Appearance: M4.
Sensing distance: 2 mm.
Connecting method: M8 Pre-wired Connector Models (0.3 m).
Cable specifications: PVC (oil-resistant).
Operation mode: NO.
Wire color /pin arrangement: 1: +V, 3: 0 V, 4: Control output.
Model: NPN output.
Ultra small size, but surprisingly easy installation!
With the addition of M4, 5 E2B-S08KN04-WP-C2 2M PDF datasheet. 4-dia., 6.5-dia. size, unshielded,
pre-wired connector model, and connector model, a total of,
108 model variations are available
E2B-S08KN04-WP-C2 2M
High-speed response frequency stably detects moving,
objects: 5 kHz max.
Four indicator lamps for easier indicator positioning.
Special mounting brackets reduce time and efforts for,
installation.
Protective Stainless-steel Spiral Tube against wire,
breakage is available (M4, M5 only) E2B-S08KN04-WP-C2 2M PDF datasheet.
Models also available with standard cables that are 5 m long,
or with robot (bending-resistant) cables. Fitting materials: Stainless steel (SUS304).
Count: 1.
Accessories: Description, Holder (upper) Holder,
(lower) Pipe Bolts M4 × 12 with Hexagonal holes,
Bolts M4 × 30 with hexagonal holes,
Phillips screws M3 × 12 (with spring and plain washers),
Spring washer M4 Plain washer M4 Nuts M4;
Material, Heat-resistant ABS resin, 66 nylon,
Stainless steel (SUS304), Iron, nickel plating,
Iron, nickel plating, Stainless steel (SUS304),
Iron, nickel plating, Iron, nickel plating,
Iron, nickel plating; Count, 1, 1, 1, 2, 1, 2, 1, 1, 3 E2B-S08KN04-WP-C2 2M PDF datasheet.
Applicable sensor (mounting pitch on sensor side): E3Z (25.4) E39-R1/E39-R3.
Page: Dimensions, 9. Control output: relay output.
Auxiliary output: 2 points.
Heating wire breakage, SSR fault detection function: single phase heater detection function.
Event input: -.
Communication: RS-485.
Terminal shape: main unit (no terminal unit).
Power supply voltage: AC/DC24V.
DIN rail operation, high performance E5 / C series of the maintenance of the most suitable system connected with a touch screen /PLC and thermostat installation type.
DIN 85mm * 22.5MM width depth guide installation type, housed in the control cabinet of the thin slender body.
The terminal platform can be easily replaced, and the maintenance performance is improved.
Through the 50ms high speed sampling, suitable for the use of high speed heating.
Easy to connect with PLC through no program communication.
The use of communication adapter cable (sold sepaarately) connected to the computer, without power supply connection
Set up。 It can be easily set by CX-Thermo (sold separately) E2B-S08KN04-WP-C2 2M datasheet PDF catalog.
With auxiliary output (maximum 2 points), event input (maximum 1 points), tthe basic function is complete E2B-S08KN04-WP-C2 2M datasheet PDF catalog.
The confirmation of a simple, eye-catching white PV display when starting or abnormal in the cabinet
(PV high 8.5mm).