Terminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 1.6 dia.
Protective tubing length L: 20 cm.
Lead wire type: Heat resistive.
Lead wire length M: 2m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E2E-C03N02-WC-B2 2M PDF datasheet.
Ideal for the thermal input devices of Temperature Controllers
E2E-C03N02-WC-B2 2M
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Item: Standard models.
Functions: Timer, Response speed change.
Model: PNP output.
Advanced Fiber Amplifier Units E2E-C03N02-WC-B2 2M PDF datasheet.
Features a Power Tuning function that optimizes light,
reception at the press of a button.
APC circuits to suppress LED aging degradation used with,
4-element LEDs.
2-channel models achieve the thinnest* profile in the industry,
at only 5 mm per channel.
2-channel models also offer AND/OR control output.
The E3X-MDA0 with two channels supports an EtherCAT Sensor.
Communications Unit or CompoNet Sensor Communications Unit E2E-C03N02-WC-B2 2M PDF datasheet. Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-485.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controlleer (auto/
manual, RUN/STOP, and alarms) and the PV or SV E2E-C03N02-WC-B2 2M datasheet PDF catalog.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E2E-C03N02-WC-B2 2M datasheet PDF catalog.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.