LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Catalog Download
OMRON E3S-CR61-M1J datasheet PDF catalog E3S-CR61-M1J PDF datasheet
Product model: E3S-CR61-M1J
Name: Oil-resistant, Long-range Photoelectric Sensor
Brand: OMRON
Sort: PDF datasheet
File language: English
Control output 1: Linear current output.
Auxiliary output: Two.
Communications: RS-485.
Heater burnout: --.
Event inputs: Two.
Power supply voltage: 24 VAC/VDC.
Large White PV Display That’s Easier to Read.
Easy to Use, from Model Selection to,
Setup and Operation.
A Complete Range of I/O Capacities,
Functions, and Performance E3S-CR61-M1J PDF datasheet.
Handles More Applications.
The white PV display with a height of 15 E3S-CR61-M1J2 mm improves visibility.
High-speed sampling at 50 ms.
Short body with depth of only 60 mm.
Easy connections to a PLC with programless communications.
Use component communications to link Temperature.
Controllers to each other. Power supply voltage: 12 to 24 VDC.
Output configuration: Open-collector output (NPN) E3S-CR61-M1J PDF datasheet.
Output code: BCD.
Resolution (divisions): 6, 8, 12.
Connection method: Pre-wired Model (1 m).
Rugged Rotary Encoder.
Absolute model.
External diameter of 50 mm.
Resolution of up to 1,024 (10-bit).
IP65 (improved oil-proof protection with sealed bearings).
Optimum angle control possible in combination with PLC or,
Cam Positioner. E32-D25Z type: standard type; standard,
Specialty: plane shape (small) head,
Bending radius (mm): R10 E3S-CR61-M1J PDF datasheet.
Standard test object (minimum test object) (mm) 1: (0.005),
Fiber element for meeting diversified needsCase color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 2.
Detection of heater burnout, SSR failure, and heater overcurrent:
Detection for single-phase heaters.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Coontroller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E3S-CR61-M1J datasheet PDF catalog.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E3S-CR61-M1J datasheet PDF catalog.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.