E32-T14F type: resistant to environmental type; resistant to drugs,
Specialty: Teflon coating side,
Shape / detection distance (mm): 500; 400; 250 (100),
Bending radius (mm): R40.
Standard test object (minimum test object) (mm) 1: 3 (0.1),
Fiber element for meeting diversified needsCase color: Black E3S-LS3NT PDF datasheet.
Control output: Current output.
Control mode *1: Standard or heating/cooling
E3S-LS3NT
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: 2.
Transfer output *2: Transfer output using control output.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance E3S-LS3NT PDF datasheet. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E3S-LS3NT PDF datasheet.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. Fitting materials: Stainless steel (SUS304).
Count: 1 .
Accessories: Description, --;
Material, --;
Count, --.
Applicable sensor (mounting pitch on sensor side): E3T-F (8).
Page: Dimensions, 12. E32-A09 type: special beam type; liquid level detection,
Special features: Anti tilt,
Bending radius (mm): R25.
Fiber element for meeting diversified needsSize: 48 x 96mm.
Control output 1: voltage output (SSR driver).
Control output 2: relay output.
Auxiliary output: 4 points (auxiliary output 2, 1 common, auxiliary output 3, 4 public general).
Power supply voltage: AC100 ~ 240V.
Terminal shape: screw terminal table type.
Input category: full range multi input.
Heating wire break, SSR fault detection function: 1 points.
Communication: RS-485.
Event input: 2 points.
Remote SP input: -.
Transfer output: -.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications.
E5AC white LCDPV display height is about 25mm.
The upper panel and the front panel are equipped with tool ports.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remote SP inputt, suitable for a wide range of applications E3S-LS3NT datasheet PDF catalog.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperrature controller is connected to each other by using the component communication E3S-LS3NT datasheet PDF catalog.
A new type of proportional control allows you to control the valve.