Terminal type: Enclosed-terminal Models.
Protective tubing length L: 100cm.
Protective tubing diameter D (mm): 10 dia.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers E3ZM-T88 PDF datasheet.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal
E3ZM-T88 Type: High-speed response models.
Connecting method: Pre-wired (2 m).
Model: PNP output.
Applicable wire-saving connector(sold separately): Type,--; Model,-- E3ZM-T88 PDF datasheet.
Stable Detection with Advanced Fiber.
Amplifier Units.
A wide range of added value with standard models with one,
input and two outputs, and ultra-long-term APC models with an,
APC life of approximately 20 years.
Power turning to easily set the optimum light level.
Automatic Power Control (APC) is always enabled to stabilize,
emitter power with high accuracy.
GIGA RAY for stable detection with the highest level of power in,
this class even for low-reflective objects and large objects E3ZM-T88 PDF datasheet.
The E3X-DA0-S supports an EtherCAT Sensor Communications,
Unit or CompoNet Sensor Communications Unit. Detection methods: the firing pattern.
Detection range: 500mm.
Purpose: small,
Small thin space probe;
Interference prevention function with close installationCase color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 2.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperaturre Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E3ZM-T88 datasheet PDF catalog.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E3ZM-T88 datasheet PDF catalog.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.