Sensing method: Through-beam type.
Sensing distance: 300 mm.
Output type: NPN output.
Output configuration: Dark-ON.
Cable length: 2 m.
Cable length from emitter to amplifier: 0.5 m.
Compact, Thin-profile.
Photomicrosensor with special amplifier.
Slim amplifier (50 × 7.5 × 12 mm) can be handled like a cable E5CN-HV201D-FLK PDF datasheet.
Provided with two operation indicators, enabling monitoring from the,
amplifier housing and sensor head
E5CN-HV201D-FLK
Simple wiring with a 3-conductor cable.
Wide operating voltage range: 12 to 24 VDC. Size: M8, Non-shielded.
Sensing distance: 4.0 mm.
Connection: M8 connector (3-pin).
Body material: Stainless steel.
Thread length (overall length): 49 (61).
Output configuration: NPN E5CN-HV201D-FLK PDF datasheet.
Operation mode NC.
Safe Mounting with Greater.
Sensing Distance.
Ensures a sensing distance approximately 1.5 to 2,
times larger than that of any conventional OMRON Sensor.
Problems such as the collision of workpieces are eliminated.
Full range of standard sizes (M8, M12, M18 and,
M30; both long and short barrels).
Modular construction simplifies customization. Appearance: Unshielded, M12 E5CN-HV201D-FLK PDF datasheet.
Sensing distance: 12 mm.
Model: Operation mode, NO.
Proximity Sensor with a Long Screw Length.
Increased tightening strength. Cable protectors,
provided as a standard feature.
Increased indicator visibility.
A milled section for wrench grip on all models. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, aalarm), interactive display PV/SV E5CN-HV201D-FLK datasheet PDF catalog.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E5CN-HV201D-FLK datasheet PDF catalog.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.