High performance price ratio standard type proximity sensor.
Standard cable protector.
The new DC two-wire type.
Non polar proximity sensor.
Type: DC three wire / wire type.
Shape: non shield, M30.
Detection range: 18mm.
Output configuration: PNP.
Action mode: NO. Large display + status indicator.
Add action mode indicator (ON/D L ON) and teaching status indicator light,
Status at a glance E5CN-RQ203L-FLK PDF datasheet
E5CN-RQ203L-FLK
Connection type: connector.
Output mode: PNP output. Size: 48 * 48mm, terminal type.
Type: control output 2 point type (power AC/DC24V).
Shell color: black.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points E5CN-RQ203L-FLK PDF datasheet.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event input points: -.
Transfer output: -.
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure E5CN-RQ203L-FLK PDF datasheet.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can perform flexible contact output.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Size: 48 * 48mm, terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase heater detection function.
Event entry point: 2.
Transfer output: -.
Communication: RS-232C.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(auutomatic / manual, RUN/RESET, alarm),
Interactive display PV/SV E5CN-RQ203L-FLK datasheet PDF catalog.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can performm flexible contact output E5CN-RQ203L-FLK datasheet PDF catalog.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.