Standard certification: No.
Action indicator: there.
Applicable load of output: DC5 2A ~ 110V.
Input rated voltage: AC200/220V.
Insulation: photo coupler.
Zero trigger function: No.
And the MY type of the same shape of the G3F series of new international standard certification (-VD type).
Achieved UL, CSA, EN (VDE certification) standard certification G2RV-1-S-AP-G DC48 PDF datasheet. (type -VD)
Socket terminal type of same size with MY (2 pole type)
G2RV-1-S-AP-G DC48
A model with an action indicator to check the status of the input. SSR with Plug-in Terminals.
The Same Shape as the G2R-1-S.
Power Relays.
These I/O solid state relays can be mounted in OMRON.
G70A I/O Terminals.
Lineup includes Input Modules for microloads and Output,
Modules for standard loads G2RV-1-S-AP-G DC48 PDF datasheet.
Lineup also includes UL, CSA, and TÜV-certified models,
(-UTU models). Number of phase: Single-phase.
Control terminal block: Terminal block with small slotted screws.
Type: Constant current.
Capacity: 60 A, 100 to 240 VAC.
Heater burnout detection: Yes.
Communications: Yes.
High-precision Control with Easy Setup,
Precise heater burnout detection.
Set value and present value monitoring with indicators G2RV-1-S-AP-G DC48 PDF datasheet.
Phase control or optimum cycle control.
RS-485 communications to set manipulated variables and,
monitor load current.
Total run time monitoring.
Output modes for phase control: proportional to phase angle,
proportional to voltage, proportional to square voltage,
and constant-current control.
Application with various loads: constant load resistance,
variable load resistance.
UL, and IEC/EN (TÜV) certified. Isolation method: Relay.
Zero cross function: No.
Operation indicator: Yes.
Applicable output load(See note.): 10 A 100 to 240 VAC.
Rated input voltage: 12 VDC.
Hybridization of a Magnetic Relay and an,
SSR Achieves 10-A Switching for 10 Million,
Operations.
UL/CSA certified (-VD models).
Using a triac to open and close the circuit reduces chattering,
and arching, thereby increasing the electrical durability to 10,
million operations.
Relays contacts for power ON and 10-A switching with high,
capaacity are provided in a compact body without the need of,
radiators G2RV-1-S-AP-G DC48 datasheet PDF catalog. Plus, there is almost no effect on heat generation,
or ambient temperature.
Operation indicators to easily check operation.
Built-in teemperature fuse prevents internal burning due to,
triac or relay malfunctions G2RV-1-S-AP-G DC48 datasheet PDF catalog.
Socket-type Relays the same size as the 1-pole and 2-pole,
LY Relays.