Isolation: Photocoupler.
Zero cross function: Yes.
Indicator: Yes.
Applicable output load(See note 2.): 10 A at 24 to 220 VAC (at 40°C).
Rated input voltage: 5 to 24 VDC.
SSR with output (5 to 90 A) at a reasonable price
Zero cross function enables less noise operation.
Built-in varistor effectively absorbs external surges G2RV-SR500-AP AC100 PDF datasheet.
Operation indicator enables monitoring operation
G2RV-SR500-AP AC100
Protective cover for greater safety.
Certified by UL, CSA and TÜV. Input capacity: 16 points.
Rated current (ON current):
0.5 A/output, 4.0 A/common.
Internal I/O common: PNP.
Residual voltage: 1.2 V max.
(0.5 ADC, between each output,
terminal and the V terminal).
Leakage current: 0.1 mA max.
ON delay: 0.5 ms max G2RV-SR500-AP AC100 PDF datasheet.
OFF delay: 1.5 ms max.
Number of circuits per common: 16 points/common.
Output indicators: LED display (yellow).
Isolation method: Photocoupler isolation.
I/O power supply method: Supply by I/O power supply.
Unit power supply current consumption: 90 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
I/O power supply current con sumption: 5 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
Weight: 180 g max G2RV-SR500-AP AC100 PDF datasheet.
Expansion functions: Enabled.
Output handling for communications errors:
Select either hold or clear.
Short-circuit protection function: No.
High-speed digital I/O terminal with the,
screw type terminal block for EtherCAT,
communications.
Detachable screw terminal block facilitates,
the maintenance.
The expansion unit can be connected.
(One expansion unit per one I/O terminal unit.)
Input/output point can be flexibly increased,
depending on the system.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary switch and with tool software.
When setting the nodes with rotary switch,
setting is easy and node identification becomes,
possible for maintenance. Safety outputs: --.
Safety standstill detection output: 3.
Auxiliary output: 2.
Rated voltage: 24 VDC.
Terminal block type: Spring-cage terminals.
Sensor-less Monitoring of Standstill for,
Machines with Long Inertia.
Standstill is monitoreed by the motor''s back electromotive force (BEMF) signal G2RV-SR500-AP AC100 datasheet PDF catalog.
Features a "Standard Configuration", allowing immediate use,
without sensitivity adjustment.
"User Configuration" also available for fine-tuning of sensitivity G2RV-SR500-AP AC100 datasheet PDF catalog.
Detailed LED indications enable easy fault diagnosis.
Safety Category 4 (EN954-1), PLe(ISO13849-1),
SIL 3 (IEC/EN 62061) certified.