LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Catalog Download
OMRON G3NA-410B AC100-240 datasheet PDF catalog G3NA-410B AC100-240 PDF datasheet
Product model: G3NA-410B AC100-240
Name: Solid State Relays
Brand: OMRON
Sort: PDF datasheet
File language: English
Isolation method: Relay.
Zero cross function: No.
Operation indicator: Yes.
Applicable output load(See note.): 10 A 100 to 240 VAC.
Rated input voltage: 5 VDC.
Hybridization of a Magnetic Relay and an,
SSR Achieves 10-A Switching for 10 Million,
Operations.
UL/CSA certified (-VD models).
Using a triac to open and close the circuit reduces chattering,
and arching, thereby increasing the electrical durability to 10,
million operations G3NA-410B AC100-240 PDF datasheet G3NA-410B AC100-240
Relays contacts for power ON and 10-A switching with high,
capacity are provided in a compact body without the need of,
radiators. Plus, there is almost no effect on heat generation,
or ambient temperature.
Operation indicators to easily check operation G3NA-410B AC100-240 PDF datasheet.
Built-in temperature fuse prevents internal burning due to,
triac or relay malfunctions.
Socket-type Relays the same size as the 1-pole and 2-pole,
LY Relays. Name: Multi-channel Power Controller.
Number of control channels: 4.
Heater burnout detection: Not supported.
Load power supply voltage: 100 to 240 VAC.
Optimum Cycle Control for High-precision.
Control with Low Noise.
Smaller than a Normal Power Controller G3NA-410B AC100-240 PDF datasheet.
Enables low-noise power control in combination with zero-cross.
SSRs. (See note.).
One Controller can control up to 8 SSRs.
RS-485 communications to set manipulated variables and,
heater burnout detection. The Smart FB Library for the G3ZA,
can also be used.
CE Marking.
Main Upgraded Functions.
Soft-start function added for lamp heaters.
Three-phase optimum cycle control added for three-phase heaters.
Combining with special CT for150-A current detection.
Note: The G3ZA must be used in combination with an SSR without the,
zero cross function when the soft-start function is used. Name: Multi-channel Power Controller.
Number of control channels: 4.
Heater burnout detection: Supported.
Load power supply voltage: 400 to 480 VAC.
Optimum Cycle Control for High-precision.
Control with Low Noise.
Smaller than a Normal Power Controller.
Enables low-noise power control in combination with zero-cross.
SSRs. (See note.).
One Controller can control up to 8 SSRs.
RS-485 communications to set manipulated variables and,
heater burnout detection. The Smart FB Library for the GG3ZA,
can also be used G3NA-410B AC100-240 datasheet PDF catalog.
CE Marking.
Main Upgraded Functions.
Soft-start function added for lamp heaters.
Three-phase optimum cycle control added for three-phase heaters.
Combining with special CT for1550-A current detection G3NA-410B AC100-240 datasheet PDF catalog.
Note: The G3ZA must be used in combination with an SSR without the,
zero cross function when the soft-start function is used.
Related products
OMRON
Temperature panel
K3HB-HTA-DRT1 AC100-240
OMRON Temperature panel K3HB-HTA-DRT1 AC100-240
Type of input: platinum resistance / the
OMRON
Temperature panel
K3HB-HTA-1 AC100-240
OMRON Temperature panel K3HB-HTA-1 AC100-240
Type of input: platinum resistance / the