Number of phase: Single-phase.
Control terminal block: Screwless clamp terminal block.
Type: Constant current.
Capacity: 60 A, 100 to 240 VAC.
Heater burnout detection: Yes.
Communications: Yes.
High-precision Control with Easy Setup,
Precise heater burnout detection.
Set value and present value monitoring with indicators G3RV-202SL DC24 PDF datasheet.
Phase control or optimum cycle control
G3RV-202SL DC24
RS-485 communications to set manipulated variables and,
monitor load current.
Total run time monitoring.
Output modes for phase control: proportional to phase angle,
proportional to voltage, proportional to square voltage,
and constant-current control.
Application with various loads: constant load resistance,
variable load resistance G3RV-202SL DC24 PDF datasheet.
UL, and IEC/EN (TÜV) certified. Isolation: Phototriac coupler.
Zero cross function: NO.
Indicator: NO.
Rated output load: 3 A at 100 to 240 VAC (See note 1.).
Rated input voltage: 5 VDC.
International Standards for G3F Series,
Same Profile as MY Power Relays.
Shape-compatible with mechanical relays.
Certified by UL, CSA, and VDE (model numbers with a suffix of“-VD”) G3RV-202SL DC24 PDF datasheet.
Socket type, same size as MY Power Relays.
Operation indicator provided to confirm input.
(model numbers with “N” before the suffix). Unit: High-density connector model.
I/O classification: Digital output.
Internal I/O common: PNP (+ common).
I/O points: 32.
I/O connections: Fujitsu connector.
Power supplyvoltage: 24 VDC.
I/O specification: 0.5 A, DC/transistor.
Digital I/O Units Compatible with MULTIPLE I/O TERMINAL,
Terminal block, connector, and high-density connector,
models are available.
The circuit block of the terminal block model can be,
mounted or dismounted for ease of maintenance without,
disconnecting the wires.
DIN track mounting. Number of phase: Single-phase.
Control terminal block: Terminal block with small slotted screws.
Type: Constant current.
Capacity: 60 A, 100 to 240 VAC.
Heater burnout detection: Yes.
Communications: Yes.
High-precision Control with Easy Setup,
Precise heater burnout detection.
Set value and present value monitoring with indicators.
Phase control or optimum cycle control.
RS-485 communicaations to set manipulated variables and,
monitor load current G3RV-202SL DC24 datasheet PDF catalog.
Total run time monitoring.
Output modes for phase control: proportional to phase angle,
proportional to voltage, proportional to square voltage,,
and constant-current control G3RV-202SL DC24 datasheet PDF catalog.
Application with various loads: constant load resistance,
variable load resistance.
UL, and IEC/EN (TÜV) certified.