Mounting type: PCB mounting.
Contact form: DPST-NO/DPST-NC.
PCB terminals.
A High-capacity, High-dielectric-strength,
Multi-pole Relay Used Like a Contactor.
Miniature hinge for maximum switching power for motor loads,
as well as resistive and inductive loads.
No contact chattering for momentary voltage drops up to 50%,
of rated voltage G3RV-SR500-D AC110 PDF datasheet.
Withstanding more than 4 kV between contacts that are differ,
ent in polarity and between the coil and contacts
G3RV-SR500-D AC110
Flame-resistant materials (UL94V-0-qualifying) used for all in,
sulation material.
Standard models approved by UL and CSA. Type: output module.
Insulation: photo coupler.
Zero crossing function: No.
Action display lamp.
Output rated voltage: DC5 3A ~ 48V G3RV-SR500-D AC110 PDF datasheet.
Input rated voltage: DC5 ~ 24V.
Logic circuit and load interface.
I/O solid state relay.
With the input module (AC, DC), the output module (AC, DC).
Product series, the color of each module to distinguish.
You can confirm the action of SSR by using the action display light.
Between input and output voltage 4000V. Isolation method: Relay.
Zero cross function: No G3RV-SR500-D AC110 PDF datasheet.
Operation indicator: Yes.
Applicable output load(See note.): 5 A 100 to 240 VAC.
Rated input voltage: 5 VDC.
Hybridization of a Magnetic Relay and an,
SSR Achieves 10-A Switching for 10 Million,
Operations.
UL/CSA certified (-VD models).
Using a triac to open and close the circuit reduces chattering,
and arching, thereby increasing the electrical durability to 10,
million operations.
Relays contacts for power ON and 10-A switching with high,
capacity are provided in a compact body without the need of,
radiators. Plus, there is almost no effect on heat generation,
or ambient temperature.
Operation indicators to easily check operation.
Built-in temperature fuse prevents internal burning due to,
triac or relay malfunctions.
Socket-type Relays the same size as the 1-pole and 2-pole,
LY Relays. Name: Multi-channel Power Controller.
Number of control channels: 4.
Heater burnout detection: Not supported.
Load power supply voltage: 100 to 240 VAC.
Optimum Cycle Control for High-precision.
Control with Low Noise.
Smaller than a Normal Power Controller.
Enables low-noise power control in combination with zero-cross.
SSRs. (See note.).
One Controller can control up to 8 SSRs.
RS-485 communications to set manipulated variables and,
heater burnout detection. The Smart FB Library for the G3ZA,
can also be used G3RV-SR500-D AC110 datasheet PDF catalog.
CE Marking.
Main Upgraded Functions.
Soft-start function added for lamp heaters.
Three-phase optimum cycle control added for three-phase heaters.
Combining with special CT for1550-A current detection G3RV-SR500-D AC110 datasheet PDF catalog.
Note: The G3ZA must be used in combination with an SSR without the,
zero cross function when the soft-start function is used.