Ontology: UL standard certification type and insert terminal type.Classification: Relay with Auxiliary Contact Block.
Structure: 4 poles + 2 poles.
Contact configuration: Relay, 3PST-NO/SPST-NC; Auxiliary Contact Block, DPST-NC.
Rated Voltage: 12, 24 VDC.
Compact Electromagnetic Contactors That.
Switch 40 A at 440 VAC G9SA-301 PDF datasheet.
One pole carries 40 A.
UL 508 and UL 840 NC contacts (resistive 40 A 480 VAC, 60 Hz, 80,000 operations)
G9SA-301
EN 60947-4-1 NC contacts (AC1 40 A 440 VAC, 50/60 Hz, 80,000 operations).
Ideal for supply power to industrial inverters, servo drivers, and other devices,
and switching power to motors and other equipment.
The maximum load capacity of 160 A when using 4-pole parallel connections G9SA-301 PDF datasheet.
EN 60947-4-1 certification for mirror contact mechanism obtained by combining,
the Relay with an Auxiliary Contact Block.
Conforms to European PV standard (VDE0126).
Approx. 30% less operation noise than a standard electromagnetic contactor.
(Approx. 100 dB reduced to approx. 70 dB.)
Approx. 50% the volume of a standard electromagnetic contactor,
to help downsize control panels G9SA-301 PDF datasheet.
According to OMRON investigation of IIEC-AC1 50 A specifications. Isolation: Phototriac Coupler.
Zero cross function: Yes.
Indicator: Yes(Yellow).
Applicable output load (See note 1.): 10 A at 24 to 240 VAC(See note 2.).
Rated input voltage: 5 to 24 VDC.
Wide Lineup of General-purpose Solid State.
Relays with Applicable Loads of 5 to 90 A.
AC Output Relays with 75-A and 90-A output currents have been,
added to the G3NA Series.
All models feature the same compact dimensions to provide a,
uniform mounting pitch.
Built-in varistor effectively absorbs external surges.
(except G3NA-D210B).
Operation indicator enables monitoring operation.
Protective cover for greater safety.
Standard models certified by UL and CSA and -UTU models by TÜV.
(except G3NA-410B, G3NA-420B, and G3NA-440B(-2)). Number of elements: 3.
Insulation method: Phototriac.
Rated supply voltage: 12 to 24 VDC.
Input method: No-voltage input (open and short circuit input).
Applicable motor: 2.2 kW (5.5 A), 380 to 400 VAC.
Soft-start/stop Function Starts and Stops.
Three-phase Motors SSmoothly and G9SA-301 datasheet PDF catalog.
Economically.
Function like an inverter by holding down the starting current.
Comply with UL, CSA, IEC (400-V models only), and JEM.
requirements.
Mount with screws or to DIN tracks.
Compact monobloock construction for the G3J-T217BL G9SA-301 datasheet PDF catalog.
(W: 100 × H: 100 × D: 110 mm) with a heat sink.
Snubber circuit and varistor are built-in.
Operation indicator.