OMRON GX-MD1621 datasheet PDF catalog GX-MD1621 PDF datasheet
Product model: GX-MD1621
Name: EtherCAT Remote I/O Terminals
Brand: OMRON
Sort: PDF datasheet
File language: English
Cable and loose wire cable with loose wire connecting terminal,
Connector cable, MITSUBISHI motor produced PLC connection cable. Cable with connector (1 to 1) /G79-_C.
L size: 5000mm.
Cable and loose wire cable with loose wire pressing connecting terminal,
Connector cable, MITSUBISHI motor produced PLC connection cable GX-MD1621 PDF datasheet. Unit: Connector model.
I/O classification: Digital input GX-MD1621
Internal I/O common: PNP (- common).
I/O points: 16.
I/O connections: Molex connector.
Power supplyvoltage: 24 VDC.
I/O specification: DC/transistor.
Digital I/O Units Compatible with MULTIPLE I/O TERMINAL,
Terminal block, connector, and high-density connector,
models are available.
The circuit block of the terminal block model can be,
mounted or dismounted for ease of maintenance without,
disconnecting the wires GX-MD1621 PDF datasheet.
DIN track mounting. Name: System Units; I/O Power Feed Unit.
Specifications: Use when the total current,
consumption of the I/O Power Supply exceeds 4 A,
or to make the I/O Power Supply a separate system.
Standards: CE, UC, L.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet GX-MD1621 PDF datasheet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Isolation: Photocoupler.
Zero cross function: Yes.
Indicator: Yes.
Applicable output load(See note 2 GX-MD1621 datasheet PDF catalog. ): 10 A at 24 to 220 VAC (at 40°C).
Rated input voltage: 5 to 24 VDC.
SSR with output (5 to 90 A) at a reasonable price
Zero cross function enables less noise operation.
Built-in varistor efffectively absorbs external surges GX-MD1621 datasheet PDF catalog.
Operation indicator enables monitoring operation.
Protective cover for greater safety.
Certified by UL, CSA and TÜV.