Type: H5CZ.
Time specifications: Timer Mode, A-2: Power ON Delay I,
b: Repeat cycle 1, E: Interval, Z: ON/OFF-duty-adjustable flicker,
Twin Timer Mode, toff: Flicker OFF Start 1, ton: Flicker ON Start 1.
Operating modes: Timer Mode A: Signal ON Delay I, A-1: Signal ON Delay II,
A-2: Power ON Delay I, A-3: Power ON Delay II, b: Repeat cycle 1,
b-1: Repeat cycle 2, d: Signal OFF Delay, E: Interval, F: Cumulative,
Z: ON/OFF-duty-adjustable flicker, S: Stopwatch, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1,
toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2 H3Y-2-B PDF datasheet
H3Y-2-B
External connections: 8-pin socket.
Inputs: None.
Outputs: Contact output (time-limit SPDT + instantaneous SPDT) Models with, instantaneous contact outputs H3Y-2-B PDF datasheet.
Supply voltage: 12 to 24 VDC/24 VAC.
Easy to Use and Easy to Read.
Basic Features.
Character height of 10 mm for better readability.
Operation is simplified by the Up/Down Keys for each digit on 4-digit.
Safety and Reliability.
Power supply circuit and input circuits are isolated for safety and reliability.
Set value limit function prevents unexpected operation of output devices H3Y-2-B PDF datasheet.
caused by setting mistakes.
Output counter function helps in managing the service life of the Timer or,
the load.
Other Features.
Models with instantaneous contact output.
Waterproof, dust-proof structure (UL508 Type 4X and IP66).
Key protection. Operation system: Time-limit operation, integrating operation.
Resetting system: Power-OFF resetting (excluding -M), external resetting,
manual resetting, automatic resetting.
No. of digits: 4 digits (switch-selectable):
0.01 to 99.99 s, 0.1 to 999.9 s, 1 to 9999 s, 0.1
to 999.9 min, 0.1 to 999.9 hrs, 1 to 9999 hrs,
1 s to 99 min 59 s, 1 min to 99 hrs 59 min.
Backup power supply function for memory protection: Can be,
enabled and disabled with a DIP switch.
DIN-sized (72 x 72 mm) Quartz Timer with,
Multiple Functions.
Wide time range from 1/100 seconds to 9999 hrs.
Built-in power supply incorporated in timer enables direct,
connection of sensors and other components H3Y-2-B datasheet PDF catalog.
Draw-out construction allows maintenance without,
disconnecting the wiring.
Power supply freely selectable within a range of 100 to 240 VAC;
a DC-operated version is also available. H3Y-2-B datasheet PDF catalog.
Control outputs of both contact type and transistor type,
simultaneously available.
Seven operating modes (N, F, C, R, K, P, and Q) are available.