LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Catalog Download
OMRON H7CX-A11-N datasheet PDF catalog H7CX-A11-N PDF datasheet
Product model: H7CX-A11-N
Name: Multifunction Counter/Tachometer
Brand: OMRON
Sort: PDF datasheet
File language: English
Display type: UP display timer (increments form 0 to the set time).
Output type: Contact output (SPDT).
Pin type: 8-pin.
Memory backup: Not provided.
Supply voltage: 100 to 240 VAC, 12 to 48 VDC.
Rated time: 0.001 to 99.99 s.
Miniature DIN-sized (48 x 48 mm) Quartz.
Timer with Abundant Series Versions H7CX-A11-N PDF datasheet.
Series version cover a wide range of rated times; 9.999 s,
99 H7CX-A11-N99 s, 999.9 s, 99 min 59 s, and 99 hrs 59 min.
Selection of elapsed time indication, remaining time indication,
contact output, and transistor output types to suit requirements.
Power supply freely selectable within a range of 100 to,
240 VAC, as well as 12 to 48 VDC.
Certified for UL and CSA safety standards. Supply voltage: 12 VDC H7CX-A11-N PDF datasheet.
Control output: Contact output, DPDT (time-limit DPDT,
or time-limit SPDT + instantaneous SPDT) Changed using a switch.
Four-mode Timer.
Multiple time ranges and operating modes let you cover a wide,
range of applications.
The time-limit DPDT output contacts can be changed to time-limit,
SPDT and instantaneous SPDT output contacts using a switch.
Sequence checks are easily performed by setting an instanta,
neous output to 0 H7CX-A11-N PDF datasheet.
Start signal control for the H3DK-M. Type: H5CX-A series.
Time specifications: 0.001 to 9.999 s, 0.01 to 99.99 s,
0.1 to 999.9 s, 1 to 9999 s, 1 s to 99 min 59 s, 0.1 to 999.9 min,
1 to 9999 min, 1 min to 99 h 59 min, 0.1 to 999.9 h, 1 to 9999 h.
Operating modes: Timer Mode, A: Signal ON Delay I, A-1: Signal ON Delay II,
A-2: Power ON Delay I, A-3: Power ON Delay II, b: Repeat cycle 1,
b-1: Repeat cycle 2, d: Signal OFF Delay, E: Interval, F: Cumulative,
Z: ON/OFF-duty-adjustablle flicker, S: Stopwatch, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1,
toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2 H7CX-A11-N datasheet PDF catalog.
External connections: Screw terminals.
Input: Signal, Reset, Gate (NPN/PNP input) H7CX-A11-N datasheet PDF catalog.
Output: Contact output (time-limit SPDT).
Supply voltage: 100 to 240 VAC.
The Timer with the Shortest Body,
in the Industry.
Related products
OMRON
Multifunction Counter/Tachometer
H7CX-A11D1-N
OMRON Multifunction Counter/Tachometer H7CX-A11D1-N
Type: H7CX-A Series. Classification: Pr
OMRON
Multifunction Counter/Tachometer
H7CX-A4-N
OMRON Multifunction Counter/Tachometer H7CX-A4-N
Type: H7CX-A Series. Classification: Pr
OMRON
Multifunction Counter/Tachometer
H7CX-A114-N
OMRON Multifunction Counter/Tachometer H7CX-A114-N
Type: H7CX-A Series. Classification: Pr
OMRON
Multifunction Counter/Tachometer
H7CX-AD-N
OMRON Multifunction Counter/Tachometer H7CX-AD-N
Type: H7CX-A Series. Classification: Pr