Type: H7CX-A Series.
Classification: Preset counter.
Configuration: 1-stage preset counter, 2-stage preset counter,
Total and preset counter, Batch counter, Dual counter, Twin counter.
External connections: Screw terminals.
Settings: 2-stage.
Display digit: 4 digits.
Outputs: Contact output (SPST + SPDT) H7CX-R11W-N PDF datasheet.
Power supply voltage: 100 to 240 VAC.
Ultra-compact Counter Provides More,
Complete Functionality
H7CX-R11W-N
Basic Features.
Short body with depth of only 59 mm (for 12 to 24-VDC Models with,
Screw Terminals).
Better readability with character height of 12 mm on 4-digit models,
and 10 mm on 6-digit models.
The present value display characters can be switched between red,
green, and orange H7CX-R11W-N PDF datasheet.
Safety and Reliability.
New set value limit and counter functions have been added.
Other Features.
Front Panel can be changed to white or light gray.
New models with two tachometer inputs and two tachometer outputs have,
been added to the series. Type: H7CX-A Series.
Classification: Preset counter.
Configuration: 1-stage preset counter; Total and preset counter.
External connections: 11-pin socket H7CX-R11W-N PDF datasheet.
Settings: 1-stage.
Display digit: 4 digits.
Outputs: Contact output (SPDT).
Power supply voltage: 100 to 240 VAC.
Ultra-compact Counter Provides More,
Complete Functionality.
Basic Features.
Short body with depth of only 59 mm (for 12 to 24-VDC Models with,
Screw Terminals).
Better readability with character height of 12 mm on 4-digit models,
and 10 mm on 6-digit models.
The present value display characters can be switched between red,
green, and orange.
Safety and Reliability.
New set value limit and counter functions have been added.
Other Features.
Front Panel can be changed to white or light gray.
New models with two tachometer inputs and two tachometer outputs have,
been added to the series. Control cycle: one year.
Output number: 4 channel.
Installation: surface mount.
Power supply voltage: AC100 ~ 240V.
Japanese label model.
The new standard for use of more convenient timing switches.
On the basis of a week of 2 channel type, the output of 4 channel type / year type also joined the series.
Use the independent key to improve the working performance significantly.
Holiday, holiday and otheer output OFF have a simple holiday set function H7CX-R11W-N datasheet PDF catalog.
Power OFF can also be set.
Test mode that can be easily recognized by the program.
In accordance with UL/CSA, electrical safety standard certification, EMC standards.
Industry first
Can reduce the sett value, achieve fast setting!
The built-in temperature compensation circuit, even in a larger temperature range,
Can also achieve high timing precision