Type: H7CX-A Series.
Classification: Preset counter/Tachometer.
Configuration: 1-stage preset counter, 2-stage preset counter,
Total and preset counter, Batch counter, Dual counter, Twin counter, Tachometer.
External connections: Screw terminals.
Settings: 2-stage.
Display digit: 6 digits.
Outputs: Transistor output (DPST) HL-5 Series PDF datasheet.
Power supply voltage: 12 to 24 VDC/24 VAC
HL-5 Series
Ultra-compact Counter Provides More,
Complete Functionality.
Basic Features.
Short body with depth of only 59 mm (for 12 to 24-VDC Models with,
Screw Terminals).
Better readability with character height of 12 mm on 4-digit models,
and 10 mm on 6-digit models.
The present value display characters can be switched between red,
green, and orange HL-5 Series PDF datasheet.
Safety and Reliability.
New set value limit and counter functions have been added.
Other Features.
Front Panel can be changed to white or light gray.
New models with two tachometer inputs and two tachometer outputs have,
been added to the series. Supply voltage: 24 VAC; 12, 24 VDC.
Time-limit contact: SPDT.
Long-time range model (0.1 min to 10 h).
Ultra-slim Timer for G2R Relay Socket HL-5 Series PDF datasheet.
Pin configuration compatible with G2R Relay and mounts to the,
P2R/P2RF Socket.
Standard multiple time ranges and multiple operating modes.
Conforms to EN61812-1 and IEC60664-1 4 kV/2 for Low Volt,
age, and EMC Directives. Preset stage: 1-stage setting.
Nameplate lettering: English.
Nine Built-in Counters/Timers to.
Measure Equipment Operating.
Cycles and Times and Forecast.
Maintenance Timing.
Provides up to nine counters or accumulative timers.
(Counter and timer functions can be used at the same time.)
Individual forecast outputs to indicate maintenance timing.
Pre-forecasst display and machine stoppage output provided HL-5 Series datasheet PDF catalog.
IP54 oil-proof type at setting area for resistance to oil and water.
Separate digit keys to easily change settings.
Compact, short-body: 72 × 72 × 79 mm (DIN).
Keey protection function prevents incorrect operation HL-5 Series datasheet PDF catalog.
Multiple outputs: NPN/PNP.
Directly connectable to 2-wire DC sensors.
Complies with UL and CSA.