Input type: DC current input.
Output type: linear; current; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with K3HB-PNB-L2AT11 AC100-240 PDF datasheet.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table
K3HB-PNB-L2AT11 AC100-240
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
DeviceNeFunction: Phase sequence, phase loss, and temperature monitoring K3HB-PNB-L2AT11 AC100-240 PDF datasheet.
Power supply voltage: 100 to 240 VAC.
Monitor Temperature Rise through.
Internal Motor Loss.
Temperature, phase sequence, and phase loss monitoring with,
the DIN 22.5-mm-sized K8AK-PT Relays.
Side-by-side mounting of K8AK-PT Relays.
Specially designed for internal motor monitoring; no setting required.
Test/Reset Button for confirmation of output operation K3HB-PNB-L2AT11 AC100-240 PDF datasheet.
Monitoring also performed for thermistor disconnections and short circuits.
Manual or automatic resetting with the same Relay. Measuring voltage: 6 to 60 mV AC/DC, 10 to 100 mV AC/DC, 30 to 300 mV AC/DC.
Supply voltage: 100-115 VAC.
Ideal for voltage monitoring for industrial.
facilities and equipment.
Monitor for overvoltages or undervoltages.
Manual resetting and automatically resetting supported by one Relay.
One SPDT output relay, 6 A at 250 VAC (resistive load).
Output relay can be switched between normally open and normally closed.
Process control signal (0 to 10 V) and current splitter input supported.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply. Measuring current: 10 to 100 A AC, 20 to 200 A (See note.).
Supply voltage: 200-230 VAC.
Ideal for current monitoring for,
industrial facilities and equipment.
Monitor for overcurrents or undercurrents.
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating timme can be set separately K3HB-PNB-L2AT11 AC100-240 datasheet PDF catalog.
One SPDT output relay, 6 A at 250 VAC (resistive load).
Output relay can be switched between normally open and,
normally closed.
Process control signal (4 to 20 mA) and coommercial CT input,
(0 to 1 A or 0 to 5 A) supported K3HB-PNB-L2AT11 AC100-240 datasheet PDF catalog.
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply.