Time specification: Inverse type.
Current setting range: 8 to 26 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage K3HB-PPB-A1 AC/DC24V PDF datasheet.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase
K3HB-PPB-A1 AC/DC24V
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-PPB-A1 AC/DC24V PDF datasheet. Error will occur in the operating,
values of the overload elements. It is recommended to test operation, Applicable Current Transformer.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload K3HB-PPB-A1 AC/DC24V PDF datasheet.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Input type: DC voltage input type.
Output type: linear; current; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC/DC24V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with.
The most suitable voltage annd current signal simulation, measurement and display, identification of the panel table K3HB-PPB-A1 AC/DC24V datasheet PDF catalog.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gaauge for monitoring the operation trend K3HB-PPB-A1 AC/DC24V datasheet PDF catalog.
External event input can be applied to a variety of measurement and identification situations.
DeviceNet type