Detect abnormal voltages applies to equipment to,
protect against equipment failure.
Use in either overvoltage or undervoltage mode.
Monitor AC or DC currents with one Relay.
Settings for the operating value, hysteresis, and operating time.
Width of 17.5 mm to reduce space required in panels.
Push-In Plus Terminal that reduce wiring work K3HB-VLC-BBCD1 AC/DC24V PDF datasheet.
The use of cage clamps enables wiring with bare stranded wires
K3HB-VLC-BBCD1 AC/DC24V
Double-insertion holes for crossover wiring (all terminals).
UL listed for easy shipping to North America.
Models added with transistor outputs for superior contact reliability. Setting range: 1 to 10 V AC/DC, 3 to 30 V AC/DC, 15 to 150 V AC/DC.
Power supply voltage: 100 to 240 VAC K3HB-VLC-BBCD1 AC/DC24V PDF datasheet.
Ideal for Voltage Monitoring for.
Industrial Facilities and Equipment.
Monitor for overvoltages and undervoltages simultaneously.
Separate settings and outputs supported for overvoltages and undervoltages.
Manual resetting and automatically resetting supported by one Relay.
Pre-alarm Monitoring Mode.
Two SPDT output relays, 5 A at 250 VAC (resistive load).
Process control signal (0 to 10 V) and current splitter input supported K3HB-VLC-BBCD1 AC/DC24V PDF datasheet.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply. Measuring voltage: 6 to 60 mV AC/DC, 10 to 100 mV AC/DC, 30 to 300 mV AC/DC.
Supply voltage: 100-115 VAC.
Ideal for voltage monitoring for industrial.
facilities and equipment.
Monitor for overvoltages or undervoltages.
Manual resetting and automatically resetting supported by one Relay.
One SPDT output relay, 6 A at 250 VAC (resistive load).
Output relay can be switched between normally open and normally closed.
Process control signal (0 to 10 V) and current splitter input supported.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply. Control supply voltage: 100 VAC; With voltage fluctuation compensation.
Operating current: 16 to 40 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal.
Precisely singles out the burned element even if one heeater el,
ement among several heater elements has been burned out K3HB-VLC-BBCD1 AC/DC24V datasheet PDF catalog.
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with booth single-phase and three-phase heaters K3HB-VLC-BBCD1 AC/DC24V datasheet PDF catalog.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage.