LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Catalog Download
OMRON K8AB-TH12S AC100-240 datasheet PDF catalog K8AB-TH12S AC100-240 PDF datasheet
Product model: K8AB-TH12S AC100-240
Name: Temperature Monitoring Relay
Brand: OMRON
Sort: PDF datasheet
File language: English
Setting range: 1 to 10 V AC/DC, 3 to 30 V AC/DC, 15 to 150 V AC/DC.
Power supply voltage: 24 VAC/DC.
Ideal for Voltage Monitoring for.
Industrial Facilities and Equipment.
Monitor for overvoltages or undervoltages.
Manual resetting and automatically resetting supported by one Relay.
One SPDT output relay, 5 A at 250 VAC (resistive load) K8AB-TH12S AC100-240 PDF datasheet.
Output relay can be switched between normally open and normally closed K8AB-TH12S AC100-240
Process control signal (0 to 10 V) and current splitter input supported.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply. Time specification: Instantaneous type.
Current setting range: 8 to 26 A K8AB-TH12S AC100-240 PDF datasheet.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button K8AB-TH12S AC100-240 PDF datasheet.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation, Static voltage relay.
K2VR-S/K2VA-S type, high action reliability disk with static type UVR/OVR.
Accurate work through high reliability semiconductor circuits K8AB-TH12S AC100-240 datasheet PDF catalog.
Type K2VU-S1 is the output contact, but will be closed when the voltage is not enough,
Therefore, the locking time sequence circuit of the circuit breaker is not required.
Within thhe hidden from the start to the 2S timer, can easily adjust the time K8AB-TH12S AC100-240 datasheet PDF catalog.
The control power of the relay is not needed, which avoids the trouble of wiring.
Related products
OMRON
Load sensor, mV instrument
K3HB-VLC-E1 AC100-240
OMRON Load sensor, mV instrument K3HB-VLC-E1 AC100-240
Category: external supply 100mA DC5V typ
OMRON
Solid State Contactor
G3J-T217BL-C AC100-240
OMRON Solid State Contactor G3J-T217BL-C AC100-240
Numer of elements: 3. Isolation method