Conduit: JIS B 0202 G½.
Applicable cable: Cabtire cable (anticorrosive).
Inner diameter (D)of seal rubber: 12.5 mm.
External diameter of cable: Min, 11 mm; Max, 13 mm.
Applicable model: WL-N, WL, D4A-@N, D4B-@N, ZE, ZV, ZV2, XE, XV, XV2.
Connectors (SC Series).
Cabtire cables and flexible tubes with various diameters are used to,
connect machine tools and controllers with Limit Switches S8FS-C20024J PDF datasheet
S8FS-C20024J To ensure,
the watertightness of the edges of the conduits, use an SC Connector,
that is suitable for the external diameter of cable and model of Limit Switch. Input voltage: 24 VDC (24 to 28 VDC).
Output voltage(during backup operation): 22.5 V.
Output current: 2.5 A.
Prevents Equipment Stoppage, Data Loss,
and Other Problems Resulting from Momentary S8FS-C20024J PDF datasheet.
Power Failures.
Provides a backup time of 500 ms at an output current of 2.5 A.
Can be wired to the 24-V output from the S8VS Supplies.
Connects to an S8TS Power Supply via an S8T-BUS03 Bus Line Connector.
Parallel connections to up to four Blocks can be used to increase,
the backup time and current capacities.
Complies with SEMI F47-0200 standard S8FS-C20024J PDF datasheet.
RoHS-compliant.
Ambient operating temperature range of –20 to 60°C. Power ratings: 240 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC)*1.
Output voltage: 24 V.
Output current: 10 A.
Alarm output *2: Sinking.
UL Class 2 Output standards: --.
Model number(screw terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that.
conform to UL Class 2 Output standards.
New mmodels with screwless terminal blocks and,
indication monitor S8FS-C20024J datasheet PDF catalog.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 ((= VDE 0805 Teil 1) S8FS-C20024J datasheet PDF catalog.
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.)