LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Catalog Download
OMRON SGE Series/SCC Series datasheet PDF catalog SGE Series/SCC Series PDF datasheet
Product model: SGE Series/SCC Series
Name: Safety Edge/Edge Controller
Brand: OMRON
Sort: PDF datasheet
File language: English
Control power supply voltage: 200/220 VAC.
Input: DC, Input voltage range, 4 to 240 mV.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL) SGE Series/SCC Series PDF datasheet.
Detect three-phase AC current for under and/or overcur,
rent using current converter SGE Series/SCC Series
Available in 7 supply voltage configurations.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verse current detection.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F) SGE Series/SCC Series PDF datasheet.
LED operation indicator.
UL/CSA approval (SDV-F@). Power ratings: 50 W.
Output voltage: 12 V.
Output current: 4.3 A.
Boost current: 6.5 A.
Newly Released High-capacity 240-W Models in S8EX-series Lineup.
Rated Output of 300 W for 200 VAC.
From 170 to 264 VAC.
New 240-W Models.
Lineup of models with 24-, 36-, and 48-VDC output.
voltages SGE Series/SCC Series PDF datasheet.
15-W, 35-W, 50-W, 100-W, and 150-W Models.
Lineup of models with from 5 to 48-VDC output.
voltages.
All Models.
Approved standards:
UL60950-1, cUR CSA C22.2 No. 60950-1, EN 50178,
and EN 60950-1.
Lineup includes open-frame models, models with.
chassis, and models with chassis and covers.
Wide-range power supply: 100 to 240 VAC.
Complies with harmonic current standard in EN.
61000-3-2 (50-W to 240-W models).
The top class in industry for compact size.
Boost current output (some models excluded). Control power supply voltage: 48 VDC.
Input: DC or AC (selectable); input voltage range: 10 to 300 V: Operating mode,
ON-delay; OFF-delay; Startup lock.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL).
Detect three-phase AC current for under and/or overcur,
rent using current converter.
Available in 7 supply voltagee configurations SGE Series/SCC Series datasheet PDF catalog.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verrse current detection SGE Series/SCC Series datasheet PDF catalog.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F).
LED operation indicator.
UL/CSA approval (SDV-F@).
Related products
OMRON
Safety Edge/Edge Controller
SGE Series/SCC Series
OMRON Safety Edge/Edge Controller SGE Series/SCC Series
Safety sensors to detect contacts y. m
Related download