LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
OMRON 3F88L-162 Manual 3F88L-162 User's Manual
Product model: 3F88L-162
Name: Digital Temperature Controllers
Brand: OMRON
Sort: User's Manual
File language: English
Function name: 3 phase 200V.
Power: 3.7KW.
Rated output voltage: 3 phase, 200 ~ 240V (the output voltage can not exceed the input voltage).
Built in brake unit (brake resistance needs to be matched).
Weight: 2.0KG.
Dimension (w * h) 128mm *:140.
Outline dimension (deep):170.5mm.
Mechanical automation concept 3F88L-162 User's Manual.
Positioning function.
The use of options.
(EtherCAT, CompoNet and DeviceNet) to realize the field bus communication 3F88L-162
Driver programming function.
Current vector control.
High starting torque: 0.5Hz up to 200%.
Safety features, in compliance with ISO13849-1:2008 EN (Cat.3/PLd) and IEC60204-1 stop level 0 standard.
Frequency output up to 580H. Function name: 3 phase 200V.
Power: 0.75KW.
Maximum output voltage: three phase 200 ~ 240VAC (corresponding input voltage) 3F88L-162 User's Manual.
Rated voltage, frequency: three-phase power supply 200 ~ 50/60Hz, 240V.
Cooling way: natural wind cooling.
Weight: 1.1kg.
Simple but not simple, casual and not casual.
Homogenization of today, the quality of the subtle show.
Standard configuration has RS485 interface, Modbus bus communication function.
3Hz provides more than 150% torque output 3F88L-162 User's Manual.
2-15kHz carrier frequency, can achieve mute driver.
Equipped with simple energy saving function.
Compact size and uniform, and can be installed close to the side by side.
Signal output function for controlling external brake action.
Software setting operation mode, no need to connect the control line can be used for speed control. Power supply: 3 phase 3 line rated voltage 500V AC.
Rated current: 25A.
Weight: 2.1KG.
Used to reduce the noise generated by the inverter.
Try to be close to the transducer for connection. Level: 3 phase 400V level.
Connnecting resistance: 34 or more 3F88L-162 Manual.
Internal resistance value: 120W, 180W * 2 (series).
In 3G3MX2 with the use of the braking resistor, can shorten the motor deceleration time.
Alarm output terminal of regenerative braking unit.
The ttemperature relay built-in resistance or braking resistance optional activation,
A circuit to cut off the main power supply of the frequency converter 3F88L-162 Manual.
Related products
OMRON
Cam positioner
3F88L-162
OMRON Cam positioner 3F88L-162
To achieve a more rapid, more advanced r
OMRON
Cam positioner
3F88L-160
OMRON Cam positioner 3F88L-160
To achieve a more rapid, more advanced r
OMRON
Enclosed Switch
D4C-1620
OMRON Enclosed Switch D4C-1620
Ratings: Standard load 5 A at 250 VAC,
OMRON
Enclosed Switch
D4C-1624
OMRON Enclosed Switch D4C-1624
Ratings: Standard load 5 A at 250 VAC,