LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
OMRON 3G2A5-RT001-PEV1 Manual 3G2A5-RT001-PEV1 INSTRUCTION SHEET
Product model: 3G2A5-RT001-PEV1
Name: Safety Light Curtain
Brand: OMRON
Sort: INSTRUCTION SHEET
File language: English
Function name: single phase 200V.
Power: 2.2KW.
Rated output voltage: 3 phase, 200 ~ 240V (the output voltage can not exceed the input voltage).
Built in brake unit (brake resistance needs to be matched).
Weight: 1.8KG.
Dimension (w * h) 128mm *:108.
Outline dimension (deep):170.5mm.
Mechanical automation concept 3G2A5-RT001-PEV1 INSTRUCTION SHEET.
Positioning function.
The use of options.
(EtherCAT, CompoNet and DeviceNet) to realize the field bus communication 3G2A5-RT001-PEV1
Driver programming function.
Current vector control.
High starting torque: 0.5Hz up to 200%.
Safety features, in compliance with ISO13849-1:2008 EN (Cat.3/PLd) and IEC60204-1 stop level 0 standard.
Frequency output up to 580H. The communication unit can connect the multi function small transducer EtherCAT to the MX2 network 3G2A5-RT001-PEV1 INSTRUCTION SHEET.
The communication unit passed the EtherCAT conformance test.
Power supply: through the inverter power supply.
Protection structure: open type (IP20). Specification: three phase 400V.
Power: 160KW.
Maximum output voltage: three phase AC380 ~ 480V (input voltage correspondence).
Rated voltage: three phase 480V ~ 50/60Hz AC380.
Weight: about 160kg 3G2A5-RT001-PEV1 INSTRUCTION SHEET.
In the inverter is equipped with the servo can play the same static torque with PG vector control function,
DeviceNet communication makes the application field more extensive.
The high functional specifications are concentrated in the compact.
Equipped with PG vector control.
Subsequent models of 3G3RV.
CV/VT selection function.
Rich online automatic adjustment function (self learning function).
CX-Drive software.
DeviceNet correspondence correspondence.
Multi function input and output function.
Colorful function.
Brake transistor built-in.
Protection function. Specificationns: Standard type 3G2A5-RT001-PEV1 Manual.
Impact resistance: 300W.
Resistance to impact resistance: 50.
The use of resistance to consume the motor regenerative energy, thereby reducing the time to slow down.
Alarm output terminal of braking resisttor 3G2A5-RT001-PEV1 Manual.
When the temperature relay of the braking resistor is activated, a circuit for cutting the main power supply of the frequency converter is formed.
Related products
OMRON
SYSBUS Remote I/O Unit
C500-RT001-V1(3G2A5-RT001-V1)
OMRON SYSBUS Remote I/O Unit C500-RT001-V1(3G2A5-RT001-V1)
C500-RT SYSMAC BUS Remote I/O Master Sla
OMRON
SYSBUS Remote I/O Unit
C500-RT201(3G2A5-RT201)
OMRON SYSBUS Remote I/O Unit C500-RT201(3G2A5-RT201)
C500-RT SYSMAC BUS Remote I/O Master Sla