LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
OMRON 3G3MX2-AB004-Z Manual 3G3MX2-AB004-Z Safety Precautions
Product model: 3G3MX2-AB004-Z
Name: Time lnterval Meter
Brand: OMRON
Sort: Safety Precautions
File language: English
Function name: single phase 200V.
Power: 2.2KW.
Rated output voltage: 3 phase, 200 ~ 240V (the output voltage can not exceed the input voltage).
Built in brake unit (brake resistance needs to be matched).
Weight: 1.8KG.
Dimension (w * h) 128mm *:108.
Outline dimension (deep):170.5mm.
Mechanical automation concept 3G3MX2-AB004-Z Safety Precautions.
Positioning function.
The use of options.
(EtherCAT, CompoNet and DeviceNet) to realize the field bus communication 3G3MX2-AB004-Z
Driver programming function.
Current vector control.
High starting torque: 0.5Hz up to 200%.
Safety features, in compliance with ISO13849-1:2008 EN (Cat.3/PLd) and IEC60204-1 stop level 0 standard.
Frequency output up to 580H. Specification: three phase 400V.
Power: 300KW 3G3MX2-AB004-Z Safety Precautions.
Maximum output voltage: three phase AC380 ~ 480V (input voltage correspondence).
Rated voltage: three phase 480V ~ 50/60Hz AC380.
Weight: about 405kg.
In the inverter is equipped with the servo can play the same static torque with PG vector control function,
DeviceNet communication makes the application field more extensive.
The high functional specifications are concentrated in the compact 3G3MX2-AB004-Z Safety Precautions.
Equipped with PG vector control.
Subsequent models of 3G3RV.
CV/VT selection function.
Rich online automatic adjustment function (self learning function).
CX-Drive software.
DeviceNet correspondence correspondence.
Multi function input and output function.
Colorful function.
Brake transistor built-in.
Protection function. Frequency converter input power: 3 phase AC400V.
Weight: 7.0KG.
Standard applicable line diameter: 38 square mm or more.
Used to suppress harmonic currents generated by a transducer.
The effect of harmonic current suppressioon is better than that of AC reactor,
And it can be used with AC reactor 3G3MX2-AB004-Z Manual. Inverter input power: 3 phase / single phase AC200V.
Weight: 0.8KG.
Standard applicable line diameter: 1.25 square mm or more.
Used to suppress harmonicc currents generated by a transducer 3G3MX2-AB004-Z Manual.
The effect of harmonic current suppression is better than that of AC reactor,
And it can be used with AC reactor.