Model: CPM2C-24EDTM. Units with 24 I/O points
2 MIL connectors.
Inputs: 16 inputs.
Outputs: 8 outputs.
Input type: 24 VDC.
Output type: sinking transistor.Model : CVM1-PRS21-EV2.
For ladder.Unit type: CS1 Special analog I/O Units.
Product name: Analog Output Units.
Specifications: I/O points, 8 outputs;
Signal range selection,
Set separately for each input;
Signal range, 4 to 20 mA;
Resolution, 1/4000 ;
Conversion speed, 1 s/point C200HX-CPU65-ZE OPERATION MANUAL
C200HX-CPU65-ZE
Externa connection, Removable erminal block.
Current consumption: 5V, 0.13A; 26V, 0.25A.
Standards: UC1, N, CE.
For Various Analog I/Os.
Analog Input Units for converting,
analog input signals into binary data.
Analog Output Units for converting ,
binary data into analog output signals C200HX-CPU65-ZE OPERATION MANUAL. Name: CS1D CPU Unit for Single CPU Systems.
Specifications: Number of I/O points,
1280 points (3 Racks);
Program capacity, 30 Ksteps;
Data Memory, 64 Kwords(DM: 32 Kwords,
EM: 32 Kwords×1 bank);
LD execution time, 0.04 μs;
Duplex CPUs, --;
Interrupt functions, OK.
Current consumption: 5V system, 0.78A;
26V system, --.
Standards: UC1, N, L, CE C200HX-CPU65-ZE OPERATION MANUAL.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables. Name: e-CON Connectors.
Specifications: Inputs; 16 inputs; PNP;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Model: C200H-OD21B.
No. of points: 32 pts.
Specifications: 24 VDC, 0.5 A (5A/Unit) .
Weight: 180g max.Unit classification: CJ1 Special I/O Units.
Product name: Temperature Control Units.
Specifications; No. of loops: 2 loops,
heater burnout detection function;
Temperature sensor inputs: Platinum ,
resistance thermometer input(JPt100, Pt100);
Control outputts: Open collector,
PNP outputs (pulses) C200HX-CPU65-ZE Manual.
No. of unit numbers allocated: 2.
Current consumption: 5V, 0.25A; 24V, --.
Standards: UC1, N, L, CE.
A Single Unit Performing All the Functions of,
4 Temperature Controllers.
A Special I/O Unit with direct input,
of thermocouple or resistance thermometer,
PID control with 2 degrees of freedom,
and open collector output C200HX-CPU65-ZE Manual.