OMRON C500-RM001-V1 Manual C500-RM001-V1 INSTRUCTION SHEET
Product model: C500-RM001-V1
Name: Safety Light Curtain
Brand: OMRON
Sort: INSTRUCTION SHEET
File language: English
Unit classification: CJ1 Special I/O Units.
name: Position control unit.
Specifications; Control method/Control,
output interface:Open-loop control by pulse,
train output/Open-collector output;
Number of control axes : 4 axes.
No. of unit numbers allocated: 2.
Current consumption: 5V, 0 C500-RM001-V1 INSTRUCTION SHEET. 36A; 24V, --.
Standards: UC1, CE.
High-speed, High-precision positioning,
with 1, 2, or 4 axes C500-RM001-V1
Versatile functions and superb performance,
enable the construction of compact,
high-performance machines.
With its ultra-compact size of 31 × 90mm (W×H),
this highly space-efficient Position Control Unit,
(PCU) enables up to 4 axes of motor control. C500-AD Special I/O Unit Analog Input C500-AD101 C500-RM001-V1 INSTRUCTION SHEET.
Input: 8 pts.
Specification: 0~+10V、4~20mA.Name: PID Control Module.
Model: C200H-PID02.
Output: Voltage output.C500-OC I/O Unit Transistor Output 16 pts C500-OC223-E(3G2A5-OC223-E).
AC250/DC24V 2A. Output method: Analog resolution: 1/256.
Analog Inputs: 2.
Analog Outputs: 1.Unit type: CS1 Special I/O Units.
Product name: Power Transducer Input Unit.
Input points : 8 inputs.
Signal range: 0 to 1 mA, ±1 mA C500-RM001-V1 INSTRUCTION SHEET.
Conversion speed (resolution):
200ms/8 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.08A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems C500-RM001-V1 Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems C500-RM001-V1 Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.