LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
OMRON CJ2H-CPU65 Manual CJ2H-CPU65 OPERATION MANUAL
Product model: CJ2H-CPU65
Name: PLC
Brand: OMRON
Sort: OPERATION MANUAL
File language: English
For 3-slot Backplane.Model: C200HS-INT01.
Rated Input Voltage: 12 to 24 VDC +10%/–15%.
Input Impedance: 2 K.
Input Current: 10 mA typical (24 VDC).
ON Voltage: 10.2 VDC min.
OFF Voltage: 3.0 VDC max.
ON Response Time: 0.2 ms max.
OFF Response Time: 0.5 ms max.
No. of Circuits: Model: CPM2C-8ET1M. Units with relay outputs only CJ2H-CPU65 OPERATION MANUAL.
1 MIL connector.
Outputs: 8 outputs.
Input type: 24 VDC CJ2H-CPU65
Output type: sourcing transistor.C500-ID I/O Unit DC Input 32 pts C500-ID215(3G2A5-ID215).
DC12-24V 10mA.Unit classification: CJ1 Special I/O Units.
Product name: Process Analog Input Units,
(Isolated-type Resistance Thermometer Input Units).
Input points: 4 inputs.
Signal range selection: Common inputs CJ2H-CPU65 OPERATION MANUAL.
Signal range: Resistance thermometer: Pt100, JPt100.
Conversion speed (resolution): Conversion,
speed: 250 ms/4 inputs.
Accuracy at ambient temperature of 25°C:
Accuracy: (±0.3% of PV or ±0.8°C,
whichever is larger) ±1 digit max.
External connection: Removable terminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.25A; 24V, --.
Standards: UC1, CE CJ2H-CPU65 OPERATION MANUAL.
A Single Unit Handling All Types of Inputs,
such as Temperature Sensor Inputs and,
Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5V).
A Unit supports four input channels,
each of which can be set to a
platinum resistance thermometer, thermocouple,
and DC signal (current, voltage).
All inputs are isolated.
Unit classifi cation: CS1 CPU Bus Unit.
Product name:Controller Link Unit.
Specifications: Communications cable,
Optical ring H-PCF cable;
Communications type, Data links and,
message service; Duplex support,
Yes. Unit duplexing and cable loop,
back are supported.
Max. Units mountable per CPU Unit,
Non-duplex: 8, Duplex: 11 (6 Units,
comprising 3 sets of Duplex Units,
+ 5 Non-duplex Units).
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.52A; 26V, --.
Standards: UC1, N, L, CE.
New Controller Link Units,
Now with 4,000 Send Words.
The Controller Link is an,
FA network that can send,
and receive large amounts,
of data easily and at high sspeed CJ2H-CPU65 Manual.
The Controller Link supports data,
links that enable sharing data between,
PLCs and computers and a message service,
that enables sending and receiving,
data whenever required.
With Wired Controller Link Units,
systeems can be flexibly built by using,
Repeater Units to enable T branches,
long-distance wiring, and converting,
part of the network to optical cable CJ2H-CPU65 Manual.
Related products
OMRON
Programmable Controllers
CJ1H-CPU65H
OMRON Programmable Controllers CJ1H-CPU65H
I/O capacity/Mountale Units Expansion R
OMRON
Programmable Controllers
CJ2H-CPU68
OMRON Programmable Controllers CJ2H-CPU68
Product name: CJ2H CPU Units. Specific
OMRON
Programmable Controllers
CJ2H-CPU68-EIP
OMRON Programmable Controllers CJ2H-CPU68-EIP
Product name: CJ2H Built-in EtherNet/I
OMRON
Programmable Controllers
CJ2H-CPU64-EIP
OMRON Programmable Controllers CJ2H-CPU64-EIP
Product name: CJ2H Built-in EtherNet/I