CPU Unit: CP1L-EM CPU Units with 40 Points.
Specifications: CPU type, Memory capacity: 10K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, DC power supply; Output method, Transistor output(sinking);
Inputs, 24; Output, 16 CP1E-E40SDR-A USER'S MANUAL.
Standards: CE.
High Performing Programmable Controller with Embedded Ethernet
CP1E-E40SDR-A
"CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port.
"CP1L-M" and "CP1L-L" has a standard-feature peripheral USB port.
Function blocks (FB) allow you to build up modular structure and,
programming of ladder diagrams. SYSMAC LINK Units can be powered up two units in one unit.
One cable included with feeder CP1E-E40SDR-A USER'S MANUAL. C500-ID Special I/O Unit ID Sensor Unit For the C500-IDS22 C500-IDA22.For C200H-PRO27-E Hand-held Programming Console ming Console.
4m.ASCII Unit
This program runs independently from the ladder-diagram program in the PLC.
Name: ASCII Module.
Model: C200H-ASC02.
ASCII/BASIC Module Utility Software: For AT-compatible computers. enables program development, downloading, uploading, etc CP1E-E40SDR-A USER'S MANUAL. Output method: Transistor sourcing.
Inputs: ---.
Outputs: 32.Unit type: CS1 Special I/O Units.
Product name: Isolated-type DC Input Unit.
Input points : 4 inputs.
Signal range: 4 to 20 mA, 0 to 20 mA,
1 to 5 V, 0 to 5 V, ±5 V, 0 to 10 V, ±10 V.
Conversion speed (resolution):
100ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.16A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previouus systems CP1E-E40SDR-A Communications Commands Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CP1E-E40SDR-A Communications Commands Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.