Model: CPM2A-30CDR-A. Power supply: AC power supply.
Output type: Relay.
Inputs points: 18 points.
Outputs points: 12 points.I/O Control UnitCV500-MC Special I/O Unit Motion Control Servo Control 4 axis CV500-MC421.Power supply: DC power supply.
Output method: Transistor output sink type.
Inputs points: 24 points CP1E-N30DR-D REFERENCE MANUAL.
Outputs points: 16 points.Name: SYSMAC LINK Module.
Model: C200HW-SLK13
CP1E-N30DR-D
Communications method: N: N token bus.
Transmission method: Manchester code, base band.
Transmission path: Daisy chain.
Weight: 500g max.Model: CPM2C-32EDTM. Units with 32 I/O points
2 MIL connectors.
Inputs: 16 inputs.
Outputs: 16 outputs.
Input type: 24 VDC.
Output type: sinking transistor.Name: Temperature Control Module CP1E-N30DR-D REFERENCE MANUAL.
Model: C200H-TC101.
Sensor: Platinum resistance thermometer: JPt100 Pt100.
Control output: Transistor output.Model: CPM2C-20CDTC-D. CPU Unit: Units with 20 I/O points.
2 Fujitsu connectors.
Inputs: 12 inputs.
Outputs: 8 outputs.
Input type: 24 VDC.
Output type: sinking transistor.
Internal clock: --.Name: Temperature Sensor Module.
Model: C200H-TS101.
Temperature sensor: RTD (JPt 100 Ω CP1E-N30DR-D REFERENCE MANUAL. ).
Input points: 4 points/Unit max. (1, 2, or 4 points can be selected).Model : C500-PS223.
100 to 120 VAC or 200 to 240 VAC (selectable).
Output ratings: 12 A, 5 VDC.Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Resistance Thermocouple Input Units.
points Input: 4 inputs.
Signal range selection:
Set separately for each input.
I/O type: Pt100, JPt100.
Conversion speed (resolution):
100 ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.15A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and spacee compared,
with previous systems CP1E-N30DR-D Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CP1E-N30DR-D Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.