Model: C200H-ID212.
No. of inputs: 16 pts.
Input voltage: 24VDC, +10%/–15%.
Input current: 7mA, 24VDC.
Isolation: Photo-coupler.
Indica-tor: LED.
External connec-tions: Remove-able termi-nal blocks.
Inputs percom-mon: 16 pts.
Internal currentcon-sump-tion: 10mA max.Product name: E@@S type CPU Units with 10 I/O Points CP1E-N40SDT1-D USER'S MANUAL.
Specifications: Power Supply, 24 VDC; Inputs, 6; Outputs, 4;
Output type: Transistor (sourcing)
CP1E-N40SDT1-D
Program capacity: 2K steps.
memory Data capacity: 2K words.
External powersupply(24 VDC): --.
Current consumption: 5 V, 0.11A; 24 V,--.
Standards: UC1, N, L, CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality CP1E-N40SDT1-D USER'S MANUAL.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection. Model: C500F-CPUA1-E(3G2C3-CPUA1-E).
C500F-CP CPU Programmable Controller C500F-CPUA1-E.Model: C200HW-COM01.
Specifications: Communications port for Controller Link, SYSMAC LINK Units.Unit type: CS1 Special I/O Units CP1E-N40SDT1-D USER'S MANUAL.
Product name: Isolated-type,
Resistance Thermocouple Input Units.
points Input: 4 inputs.
Signal range selection:
Set separately for each input.
I/O type: Pt100, JPt100, Pt50, Ni508.4.
Conversion speed (resolution):
20 ms/4 inputs, 10 ms/2 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.12A; 26V, 0.07A.
Standards: UC1, N, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previouss systems CP1E-N40SDT1-D Communications Commands Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CP1E-N40SDT1-D Communications Commands Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.