Unit type: CJ1 CPU Bus Units.
Product Name: Serial Communications,
Units High-speed type.
Specifications:Communications Interface,
2 RS-422A/485 ports; Communications functions,
The following functions can be selected,
for each port with an CJ system:
Protocol macro, Host Link, NT Links (1:N mode),
Serial Gateway, No-protocol, Modbus-RTU Slave,
The following functions can be selected,
for each port with an NJ system: Protocol macro,
Serial Gateway, No-protocol, Modbus-RTU Slave CP1E-N60S1DT-D PROGRAMMING MANUAL
CP1E-N60S1DT-D
No. of unit numbers allocated: 1.
Current consumption : 5V, 0.40A; 24V,--.
Standards: UC1, N, L, CE.
The Serial Communications Units That Enable,
High-speed Connections with External Devices.
Each Serial Communications Unit provides two,
serial communications ports: RS-232C and,
RS-422A/485, and the serial communications,
mode can be set separately for each port from,
Protocol Macro, Host Link, NT Link,
Serial Gateway, and No-protocol CP1E-N60S1DT-D PROGRAMMING MANUAL. Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Thermocouple Input Units.
points Input: 4 inputs.
Signal range selection:
Set separately for each input CP1E-N60S1DT-D PROGRAMMING MANUAL.
I/O type: B, E, J, K, L, N, R, S,
T, U, WRe5-26, PLII, ±100 mV.
Conversion speed: 20 ms/4 inputs,
10 ms/2 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.12A; 26V, 0.08A.
Standards: UC1, N, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,,
with previous systems CP1E-N60S1DT-D Hardware Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CP1E-N60S1DT-D Hardware Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.