I/O capacity/Mountable Units(Expansion Racks): 1, 280 points/40 Units (3 Expansion Racks max.).
CJ1G-CPU44H Program capacity: 30K steps.
CPU Unit CJ1G-CPU44H Data memory capacity: 64K words(DM: 32K words, EM: 32K words × 1 bank).Name: Bit Slave Units with e-CON Connectors.
Specifications: Outputs; 2 outputs; PNP CP1L-EM40DT-D OPERATION MANUAL.
Simple and Intelligent Bit Slaves,
with Industry-standard e-CON connectors
CP1L-EM40DT-D
Slave Units capable of 2-point bit-level distribution.
The I/O power supply is supplied from the communications,
power in the previously connected flat cable, and has a,
short-circuit detection function for protection.
Industry-standard e-CON connectors.
Short-circuit protection safeguards the network,
from I/O short circuits CP1L-EM40DT-D OPERATION MANUAL.
Simple communications connections,
with flat cable and connectors.
Bit-level distribution to support,
essentially any application. Unit type: CS1 Special analog I/O Units.
Product name: Analog I/O Units.
Specifications: I/O points,
4 inputs, 4 outputs;
Signal range selection,
Set separately for each input;
Signal range, 1 to 5 V, 0 to 5 V,
0 to 10 V, -10 V to 10 V, 4 to 20 mA;
Resolution, 1/4000 ;
Conversion speed, 1 s/point CP1L-EM40DT-D OPERATION MANUAL.
Externa connection, Removable erminal block.
Current consumption: 5V, 0.20A; 26V, 0.20A.
Standards: UC1, N, L, CE.
For Various Analog I/Os.
Analog Input Units for converting,
analog input signals into binary data.
Analog Output Units for converting ,
binary data into analog output signals. Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Resistance Thermocouple Input Units.
points Input: 4 inputs.
Signal range selection:
Set separately for each input.
I/O type: Pt100, JPt100, Pt50, Ni508.4.
Conversion speed (resolution):
20 ms/4 inputs, 10 ms/2 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.12A; 26V, 0.07A.
Standards: UC1, N, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems CP1L-EM40DT-D Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CP1L-EM40DT-D Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.