Name: CS1D Duplex Unit.
Specifications: Applicable systems,
Duplex CPU, Dual I/O Expansion System only;
Basic functions, Duplex CPU Unit processing,
error monitoring, and CPU Unit switching,
when error occurs;
Online Replacement, Supported.
Current consumption: 5V system, 0.41A;
26 V system, -- CP1L-M30DR-D OPERATION MANUAL.
Standards: UC1, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables
CP1L-M30DR-D I/O points: 256 pts.
Program capacity(words): 7.2 K.
DM capacity (words): 6 K.
RS-232C port: YES.
Analog setting: YES.One Ethernet Option Board can be mounted in either option board slot 1 or 2.
Note: Cannot be used for the CP1L-L10.C500-OA I/O Unit Triac Output 16 pts C500-OA226 CP1L-M30DR-D OPERATION MANUAL.
AC250V 1.2A.Analog inputs: 4 points.Model: CPM2A-30CDT-D. Power supply: DC power supply.
Output type: Transistor sinking.
Inputs points: 18 points.
Outputs points: 12 points.Output type: Transistor sinking.
Inputs points: 24 points.
Outputs points: 16 points.Name: Connector.
Model: C200H-CE002.Name: Loop-control CPU Unit.
I/O bits: 960 bits.
Program capacity: 10K steps.
DM words: 32K words CP1L-M30DR-D OPERATION MANUAL.
EM words: 32K words × 1 bank E0_00000 to E0_32767.
Versatile Machine Control with the,
Highest Performance Standards in the Industry. Unit type: CS1 Basic I/O Units.
Product name: B7A Interface Unit.
Specifications: 16 inputs/outputs.
Mountable Racks: CPU Rack, CS1W-BC,
@@3, Yes, @@2, Yes;
C200HX/HG/HE Expansion I/O Rack, No.
CS1 Expansion Rack, CS1W-BI,
@@3, Yes, @@2, Yes;
CS1 Long distance Expansion Rack, Yes;
SYSMAC BUS Slave Rack, No.
Words required: 1 input word and 1 output word.
Current consumption: 5V system, 0.09A;
26 V system, --.
Standards: UC1, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control. Name: e-CON Connectors.
Specifications: Inputs/Outputs;
16 inputs /16 outputs; NPN;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost cann be reduced CP1L-M30DR-D Manual.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CP1L-M30DR-D Manual.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.