8 pts, 1 A, 120 VAC.Unit type: CJ1 CPU Bus Units.
Product Name: Serial Communications nits.
Specifications:Communications Interface,
1 RS-232C port and 1 RS-422A/485 port;
Communications functions,
The following functions can be,
selected for each port:
Protocol macro Host Link,
NT Links (1:N mode)Serial Gateway,
No-protocol Modbus-RTU Slave CPM1A-20CDR-A-V1 HOST CONNECTION MANUAL.
No
CPM1A-20CDR-A-V1 of unit numbers allocated: 1.
Current consumption : 5V, 0.38A; 24V,--.
Standards: UC1, N, L, CE.
The Serial Communications Units That Enable,
High-speed Connections with External Devices.
Each Serial Communications Unit provides two,
serial communications ports: RS-232C and,
RS-422A/485, and the serial communications,
mode can be set separately for each port from,
Protocol Macro, Host Link, NT Link,
Serial Gateway, and No-protocol CPM1A-20CDR-A-V1 HOST CONNECTION MANUAL. Unit type: CJ1 Basic I/O Units.
Product name: Transistor Output Units.
Specifications: Output type, Sinking;
I/O points, 32 outputs;
Maximum switching capacity, 12 to 24VDC, 0.5A;
Commons, 16 points, 1 common;
External connection, MIL connector.
No. of words allocated: 2 words CPM1A-20CDR-A-V1 HOST CONNECTION MANUAL.
Current consumption: 5V, 0.14A; 24V, --.
Standards: UC1, N, L, CE.
A Wide Range of Basic Output,
Units for High Speed Output,
and Different Applications.
These Output Units receive the ,
results of output instructions ,
from the CPU Unit and perform ON/OFF,
control for external devices.
High-speed Output models CJ1W-OD213 and,
CJ1W-OD234 can help to increase system.
throughput. Number of outputs: 8 pts.
Max. switch-ing capacity: 2 A at 24 V DC.
External connector: Terminal block.
Weight: 200 g max.Unit classification: CJ1 Special I/O Units.
Product name: Process Analog Input Units,
(Isolated-type Resistance Thermometer Input Units).
Input points: 4 inputs.
Signal range selection: Common inputs.
Signal range: Resistance thermometer: Pt100, JPt100.
Conversion speed (resolution): Conversion,
speed: 250 ms/4 inputs.
Accuracy at ambient temperature of 25°C:
Accuracy: (±0.3% of PV or ±0.8°C,
whichever is larger) ±1 digit max.
External connection: Removable terminal block.
No. of unit numbers allocated: 1.
Currentt consumption: 5V, 0 CPM1A-20CDR-A-V1 Manual. 25A; 24V, --.
Standards: UC1, CE.
A Single Unit Handling All Types of Inputs,
such as Temperature Sensor Inputs and,
Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5V).
A Unit supports four inputt channels,
each of which can be set to a
platinum resistance thermometer, thermocouple,
and DC signal (current, voltage) CPM1A-20CDR-A-V1 Manual.
All inputs are isolated.