OMRON CPM2B-32C1DT-D Manual CPM2B-32C1DT-D Installation Guide
Product model: CPM2B-32C1DT-D
Name: Programmable Terminals
Brand: OMRON
Sort: Installation Guide
File language: English
Model: C500-BC051.
5 slots(3 linkable slots).
C500-CT/3G2A5-CT Special I/O Unit High-speed Counter Unit 50 kcps 1 pts C500-CT012(3G2A5-CT012).CV500-VP CPU Bus Unit Personal Computer Unit Main Mem CV500-VP217.
8-MB memory; w/o floating-point processor.Product name: N@@-type CPU Units with 30 I/O Points CPM2B-32C1DT-D Installation Guide.
Specifications: Power Supply, 24 VDC; Inputs, 8; Outputs, 6;
Output type: Transistor (sourcing) CPM2B-32C1DT-D
Program capacity: 8K steps.
memory Data capacity: 8K words.
External powersupply(24 VDC): --.
Current consumption: 5 V, 0.22A; 24 V,0.02A.
Standards: UC1, N, L, CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality CPM2B-32C1DT-D Installation Guide.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection. NO. OF I/O SLOTS: 4 SLOTSName: Three-tier Screw Terminal Block.
Specifications: Inputs/Outputs;
8 inputs/8 outputs; NPN;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet CPM2B-32C1DT-D Installation Guide.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. vName: Two-tier Screw Terminal Block.
Specifications: Inputs/Outputs;
8 inputs/8 outputs; NPN.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can bbe reduced CPM2B-32C1DT-D Manual.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CPM2B-32C1DT-D Manual.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.