Unit type: CS1 Special I/O Units.
Name: CompoBus/S Master Unit.
Specifications: Communications,
functions, Remote I/O communications;
No. of I/O points, 256 max.
(128 inputs and 128 outputs), 128 max.
(64 inputs and 64 outputs);
Max. Units mountable per CPU Unit, 95, 96.
No. of unit numbers allocated: 2; 1 CQM1H-CPU11 OPERATION Manual.
Current consumption: 5V, 0.15A; 26V, --.
Standards: U, C, CE
CQM1H-CPU11
CompoBus/S is a high-speed I/O bus. Unit type: CJ1 Basic I/O Units.
Product name: Transistor Output Units.
Specifications: Output type, Sinking;
I/O points, 16 outputs;
Maximum switching capacity, 12 to 24VDC, 0.5A;
Commons, 16 points, 1 common;
External connection, Removable terminal block.
No. of words allocated: 1 word CQM1H-CPU11 OPERATION Manual.
Current consumption: 5V, 0.10A; 24V, --.
Standards: UC1, N, L, CE.
A Wide Range of Basic Output,
Units for High Speed Output,
and Different Applications.
These Output Units receive the ,
results of output instructions ,
from the CPU Unit and perform ON/OFF,
control for external devices.
High-speed Output models CJ1W-OD213 and,
CJ1W-OD234 can help to increase system CQM1H-CPU11 OPERATION Manual.
throughput. I/O bits: 960 (Expan-sion Racks: 2).
Program capacity: 10K steps.
Data memory capacity: 64K words (DM: 32K words, EM: 32K words ×1 bank)Product name: N@@S1- type CPU Units with 30 I/O Points.
Specifications: Power Supply, 100 to 240 VAC; Inputs, 18; Outputs, 12;
Output type: Relay.
Program capacity: 8K steps.
memory Data capacity: 8K words.
External powersupply(24 VDC): 0.30A.
Current consumption: 5 V, 0.21A; 24 V,0.07A.
Standards: CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection. Name: Two-tier Screw Terminal Block.
Specifications: Outputs; 16 outputs; NPN.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost caan be reduced CQM1H-CPU11 Manual.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CQM1H-CPU11 Manual.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.