CV500-CN Cable Motion Control Connecting Cables 2 m CV500-CN224CPU Unit: CP1L-EL CPU Units with 20 Points.
Specifications: CPU type, Memory capacity: 5K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, DC power supply; Output method, Relay output;
Inputs, 12; Output, 8 CRT1-AD04 REFERENCE MANUAL.
Standards: CE.
High Performing Programmable Controller with Embedded Ethernet
CRT1-AD04
"CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port.
"CP1L-M" and "CP1L-L" has a standard-feature peripheral USB port.
Function blocks (FB) allow you to build up modular structure and,
programming of ladder diagrams. Type: CJ1 Special I/O Unit.
Connected ID System: V680 Series; 1 Head CRT1-AD04 REFERENCE MANUAL.
External power supply: --.
No. of unit numbers used: 1 unit number.
Current consumption: 5V, 0.26A;
24V, 0.13A; External, --.
Communication Unit Dedicated for RFID V680,
Allowing Direct Connection to OMRON PLC CJ/
CS/NJ-series.
Communication unit for connecting RFID V680-series,
which can be used around the world, directly to PLC.
Allows batch transfer of data up to 32 kbytes CRT1-AD04 REFERENCE MANUAL. Meet the standard interface IEEE-488-1978 (GP-IB).Supply voltage: 100 to 120 or 200 to 240 VAC (automatic voltage setting), 50/60 Hz
Operating voltage range: 85 to 132 or 170 to 264 VAC
Power consumption: 150 VA max.
Output capacity: 8 A, 5 VDCPower supply: AC power supply.
Output method: Transistor output sink type.
Inputs points: 18 points.
Outputs points: 12 points.Output method: Analog resolution: 1/6000.
Analog Inputs: 4.Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Thermocouple Input Units.
points Input: 8 inputs.
Signal range selection:
Set separately for each input.
I/O type: R, S, K, J, T, L, B.
Conversion speed: 250 ms/8 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.18A; 26V, 0.06A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and sppace compared,
with previous systems CRT1-AD04 Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CRT1-AD04 Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.