CPU Unit: CP1L-M CPU Units with 40 Points.
Specifications: CPU type, Memory capacity: 10K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, DC power supply; Output method, Transistor output (sourcing);
Inputs, 24; Output, 16 CS1D-DPL01 OPERATION MANUAL.
Standards: UC1, N, L, CE.
High Performing Programmable Controller with Embedded Ethernet
CS1D-DPL01
"CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port.
"CP1L-M" and "CP1L-L" has a standard-feature peripheral USB port.
Function blocks (FB) allow you to build up modular structure and,
programming of ladder diagrams. Model: CPM2C-32CDTM-D. CPU Unit: Units with 32 I/O points.
2 MIL connectors CS1D-DPL01 OPERATION MANUAL.
Inputs: 16 inputs.
Outputs: 16 outputs.
Input type: 24 VDC.
Output type: sinking transistor.
Internal clock: --.Output method: Relay.
Inputs: 24.
Outputs: 16.ASCII Unit
This program runs independently from the ladder-diagram program in the PLC.
Name: ASCII Module.
Model: C200H-ASC02.
ASCII/BASIC Module Utility Software: For AT-compatible computers. enables program development, downloading, uploading, etc CS1D-DPL01 OPERATION MANUAL. Model: C200H-BC051-V2.
No. of I/O slots: 5 slots.Product name: N@@-type CPU Units with 40 I/O Points.
Specifications: Power Supply, 100 to 240 VAC; Inputs, 24; Outputs, 16;
Output type: Transistor (sinking).
Program capacity: 8K steps.
memory Data capacity: 8K words.
External powersupply(24 VDC): 0.30A.
Current consumption: 5 V, 0.31A; 24 V,0.02A.
Standards: UC1, N, L, CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection. Name: Clamp Terminal Blocks.
Specifications: Outputs; 8 outputs ; PNP; --.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost ccan be reduced CS1D-DPL01 Manual.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CS1D-DPL01 Manual.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.