Model: CPM2C-20CDR-D. CPU Unit: Units with 20 I/O points.
I/O terminal block.
Inputs: 12 inputs.
Outputs: 8 outputs.
Input type: 24 VDC.
Output type: relay.
Internal clock: --.Model: C200H-OC226N.
No. of points: 16 pts.
Specifications: 2A, 250VAC/24VDC(For resistive loads).Name: Clamp Terminal Blocks CS1W-PDC11 OPERATION Manual.
Specifications: Outputs; 16 outputs ; PNP; --.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet
CS1W-PDC11
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site CS1W-PDC11 OPERATION Manual.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. C500-ID Special I/O Unit ID Sensor Unit General Purpose C500-IDS01-V2C500-RT SYSMAC BUS Remote I/O Master Slave Wired C500-RT002-PV1.
APF/PCF.With two optical connectorsCPU Unit: CP1L-M CPU Units with 60 Points.
Specifications: CPU type, Memory capacity: 10K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, AC power supply; Output method, Relay output;
Inputs, 36; Output, 24 CS1W-PDC11 OPERATION Manual.
Standards: UC1, N, L, CE.
High Performing Programmable Controller with Embedded Ethernet.
"CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port.
"CP1L-M" and "CP1L-L" has a standard-feature peripheral USB port.
Function blocks (FB) allow you to build up modular structure and,
programming of ladder diagrams. C500-GP Special I/O Unit GPIB Interface Unit C500-GPI01.Unit type: CJ1 Special I/O Units.
Product name: Analog Output Unit.
I/O points: 4 inputs ; 2 outputs.
Signal range selection:
Set separately for each input and output.
Signal range, Resolution: 1 to 5 V,
0 to 5 V, 0 to 10 V, -10 to 10 V,
4 to 20 mA.
Resolution: 1/4,000 (Settable to 1/8,000).
Conversion period: 1 ms/point,
(Settable to 500 μs/point).
Accuracy at ambient temperature of 25°C:
Voltage: ±0.2% of F.S. Current: ±0.2% of F.S;
Voltage: ±0.3% of F.S. Current: ±0.3% of F.S.
External connection: Removable terminal block.
External power supply:: 24 VDC +10% -15%, 140mA max CS1W-PDC11 Manual.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.58A; 24V, --.
Standards: UC1, N, L, CE.
Consistent Microsecond Throughput:
Models with Direct Conversion Join the Lineup.
Anaalog Input Units for converting analog input,
signals into binary data CS1W-PDC11 Manual.
Analog Output Units for converting binary ,
data into analog output signals.