Unit classification: CJ1 Special I/O Units.
Product name: ProcessInput Units,
(Isolated-type Thermocouple Input Units).
Input points: 4 inputs.
Signal range selection: Common inputs.
Signal range: Thermocouple: R, S, K, J, T, L, B.
Conversion speed (resolution): Conversion,
speed: 250 ms/4 inputs CS1W-V600C12 OPERATION MANUAL.
Accuracy at ambient temperature of 25°C:
Accuracy: (±0
CS1W-V600C123% of PV or ±1°C,
whichever is larger) ±1 digit max.
External connection: Removable terminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.25A; 24V, --.
Standards: UC1, CE.
A Single Unit Handling All Types of Inputs,
such as Temperature Sensor Inputs and,
Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5V) CS1W-V600C12 OPERATION MANUAL.
A Unit supports four input channels,
each of which can be set to a
platinum resistance thermometer, thermocouple,
and DC signal (current, voltage).
All inputs are isolated. Name: e-CON Connectors.
Specifications: Inputs; 32 inputs; NPN;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet CS1W-V600C12 OPERATION MANUAL.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Thermocouple Input Units.
points Input: 4 inputs.
Signal range selection:
Set separately for each input.
I/O type: R, S, K, J, T, L, B.
Conversion speed: 250 ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.25A; 26V, --.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and spacee compared,
with previous systems CS1W-V600C12 Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CS1W-V600C12 Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.