C500-RT SYSMAC BUS Remote I/O Master Slave Wired C500-RT001-PV1.
APF/PCF, With the optical connector 1.Name: CS1D CPU Unit for Duplex CPU Systems.
Specifications: Number of I/O points,
5,120 points (7 Racks);
Program capacity, 250 Ksteps;
Data Memory, 448 Kwords,
(DM: 32 Kwords, EM: 32 Kwords ×13 banks);
LD execution time, 0 CVM1-CPU21-V2 Macro Reference. 02 μs;
Duplex CPUs, OK;
Interrupt functions, --
CVM1-CPU21-V2
Current consumption: 5 V system, 0.82A;
26 V system, --.
Standards: UC1, N, L, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables. CPU Unit: CP1L-M CPU Units with 30 Points.
Specifications: CPU type, Memory capacity: 10K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, DC power supply; Output method, Transistor output (sinking);
Inputs, 18; Output, 12 CVM1-CPU21-V2 Macro Reference.
Standards: UC1, N, L, CE.
High Performing Programmable Controller with Embedded Ethernet.
"CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port.
"CP1L-M" and "CP1L-L" has a standard-feature peripheral USB port.
Function blocks (FB) allow you to build up modular structure and,
programming of ladder diagrams CVM1-CPU21-V2 Macro Reference. Terminal Resistance Unit Mount to an I/O Expansion Unit CV500-TER01Name: Three-tier Screw Terminal Block.
Specifications: Outputs; 8 outputs; NPN;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. C500-AS Special I/O Unit ASCII Unit C500-ASC04.Unit type: CJ1 Basic I/O Units.
Product name: DC Input/Transistor Output Units.
Specifications: Output type, Sinking;
I/O points, 32 inputs, 32 outputs;
Input voltage,Input current, 24VDC, 4.1mA,
12 to 24VDC, 0.3A;
Commons, 16 points, 1 common;
External connection, Fujiitsu connector CVM1-CPU21-V2 Cv Support Sortware Version 2: Offline Manual.
No. of words allocated: 4 words.
Current consumption: 5V, 0.14A; 24V, --.
Standards: UC1, N, CE.
A Wide Range of Basic Mixed,
I/O Units for Different Applications,,
and Wiring Methods CVM1-CPU21-V2 Cv Support Sortware Version 2: Offline Manual.
One Mixed I/O Unit has connectors for,
both inputs and outputs.
Use Mixed I/O Units to easily ,
build space-saving systems.