LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
OMRON CXONE-AL30D-V4-UP CX-Motion-MCH Manual CXONE-AL30D-V4-UP Operation Manual
Product model: CXONE-AL30D-V4-UP
Name: Host Link Units
Brand: OMRON
Sort: CX-Motion-MCH Operation Manual
File language: English
Unit classification: CJ1 CPU Bus Units.
Product name: Motion Control Unit with,
MECHA TROLINK-II interface.
Specifications: Control modes : Position,
speed, or torque control via MECHATROLINK-II,
Control axes : 32 axes max. (30 physical axes,
2 virtua axes).
Internal programming language: Special motion contro
language
No CXONE-AL30D-V4-UP Operation Manual. of unit numbers allocated: 1 CXONE-AL30D-V4-UP
Current consumption: 5V, 0.60A; 24V, --.
Standards: UC1, CE.
Improve Equipment Design Efficiency,
and Shorten Tact Time.
Control Servos for up to 16 axes in,
a motion network with one Position,
Control Unit that supports MECHATROLINK-II.
MECHATROLINK-II is a registered trademark,
of the MECHATROLINK Members Association. Model: C200H-TS002 CXONE-AL30D-V4-UP Operation Manual.
Temperature sensor: Thermocou-ples: K (CA)/L (Fe-CuNi)(DIN)(selectable)
Input points: 4 points/Unit max. (1, 2, or 4 points can be selected)C1000H-CP CPU 62 k words 1024 pts C1000H-CPU01-E.Name: CS1D CPU Unit for Single CPU Systems.
Specifications: Number of I/O points,
5,120 points (7 Racks);
Program capacity, 250 Ksteps;
Data Memory, 448 Kwords(DM: 32 Kwords,
EM: 32 Kwords×13 banks);
LD execution time, 0 CXONE-AL30D-V4-UP Operation Manual. 02 μs;
Duplex CPUs, --;
Interrupt functions, OK.
Current consumption: 5V system, 0.82A;
26V system, --.
Standards: UC1, N, L, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables.
Model: C200H-DA003.
Input points: 8.
Voltage input: 1 to 5V or 10 to 10 V or –10 to 10 V.Unit type: CS1 Special I/O Units.
Product name: Analog Input Unit (100 mV).
Input points : 8 inputs.
Signal range: 0 to 100 mV, ±100 mV.
Conversion speed (resolution):
200ms/8 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.08A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with pprevious systems CXONE-AL30D-V4-UP CX-Motion-MCH Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CXONE-AL30D-V4-UP CX-Motion-MCH Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.
Related products