Power supply voltage: 12 to 24 VDC.
Output configuration: PNP open-collector output.
Resolution (pulses/rotation): 100, 200, 360, 500, 600; 1,000; 2,000.
General-purpose Encoder with.
External Diameter of 40 mm.
Incremental model.
External diameter of 40 mm.
Resolution of up to 2,000 ppr. Size: 48 * 48mm, terminal type E5AC-TCX4DSM-060 lnstruction Manual.
Category: control output 1 point type (power supply AC100 ~ 240V)
E5AC-TCX4DSM-060
Shell color: black.
Control output: linear voltage output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: -.
Event input points: -.
Transfer output: output (using control output).
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved E5AC-TCX4DSM-060 lnstruction Manual.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors E5AC-TCX4DSM-060 lnstruction Manual.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can perform flexible contact output.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Detection methods: the firing pattern.
Detection range: 1m.
Purpose: small,
Small thin space probe;
Interference prevention function with close installationSize: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: transfer output (special terminal).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarmm), interactive display PV/SV E5AC-TCX4DSM-060 RS-485 CompoWay/F Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E5AC-TCX4DSM-060 RS-485 CompoWay/F Manual.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.