Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 4.8 dia.
Protective tubing length L: 50 cm.
Lead wire type: Standard.
Lead wire length M : 4m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E5AN-C3BBFT-N User's Manual.
Ideal for the thermal input devices of Temperature Controllers
E5AN-C3BBFT-N
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Ontology: basic.
Size: 48 x 96mm.
Type: basic type (1 input)
Control mode: standard control, heating and cooling control E5AN-C3BBFT-N User's Manual.
Output (control / transfer) points: 2 point (pulse voltage + pulse voltage / current).
Output (SUB) points: 4 points.
Event entry point: 2.
Serial communication: -.
High speed, high precision and multiple input and output universal digital regulator,
Liquid crystal display device with high visibility 5 bit and 3 line.
The high speed sampling period is suitable for the operation of high speed response E5AN-C3BBFT-N User's Manual.
With a backlight liquid crystal display and the 3 display, can display the current value, the target value, the amount of operation.
1 digital controller can be multi point control / series control / proportion control.
Standard is equipped with a variety of computing functions.
Equipped with DeviceNet communication function.
Data setting and data monitoring can be performed by means of a communication program. Size: 96 × 96 mm.
Control type: Basic control (1 loop).
Control mode: 1 loop for standard control,
Single-loop heating and cooling control.
Outputs(control/transfer): 2 points: Current and Current.
Optional functions: Auxiliary outputs (SUB), 4;
Event inputs, 2; Serial communications, Yes.
E5AR Digital Controllers offer high speed,
high precision, and multiple I/O and use a 5-digit,
3-row LCD display for high visual clarity.
A short sampling period of 50 ms enables use in applications,
requiring high-speed response.
PV, SP, and MV data is displayed simultaneously in a 3-row,
negative LCD display with a backlight.
Multiloop control, cascade control, and proportional control are,
possible with a single Controller.
When using modeels with CompoWay/F communications, initial,
settings can be downloaded and settings can be masked using,
Support Software (CX-Thermo version 4 E5AN-C3BBFT-N Manual. 0 or higher).
Equipped with calculation functions as a standard (e.g., square,
root calculation and broken-line approximation) E5AN-C3BBFT-N Manual.
DeviceNet Communications.
Data setting and monitoring can be performed without special programming.