LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
OMRON E5AN-HAA2HH01BFD-FLK Manual E5AN-HAA2HH01BFD-FLK Basic Type
Product model: E5AN-HAA2HH01BFD-FLK
Name: Digital Temperature Controller E5AN-HAA2HH01BFD-FLK Basic Type OMRON E5AN-HAA2HH01BFD-FLK Manual
Brand: OMRON
Sort: Basic Type
File language: English
Appearance: Shielded, M18.
Sensing distance: 8 mm.
Output: PNP.
Model: Operation mode NO.
Aluminum and Iron Both.
Detectable from Long Distances. Size: DIN 1/4, 96 x 96 x 78mm.
Power supply voltage: AC100 ~ 240V.
Alarm points: 3 points.
Control output: current.
Input: thermocouple.
New generation intelligent general temperature controller E5AN-HAA2HH01BFD-FLK Basic Type.
The thickness is only 78 mm E5AN-HAA2HH01BFD-FLK
Various temperature inputs: thermocouple, platinum resistance, non contact temperature sensor signal input.
Automatic adjustment and self adjustment.
Automatic adjustment can be performed even when the self adjustment is being performed.
Can use heating or heating / cooling control.
Event entry allows multiple SP options and run / stop functions E5AN-HAA2HH01BFD-FLK Basic Type. Appearance: L-shaped.
Sensing method: Through-beam type (with slot).
Cable length: 2 m.
Sensing distance: 5 mm (slot width).
configuration Output: Light-ON.
Indicator mode: No incident light.
Model: NPN output.
Slim, Compact Photomicrosensor.
that is still easy to use.
Compact, thin profile enables dense mounting.
Indicator is visible from both sides.
Wide operating voltage range: 5 to 24 VDC E5AN-HAA2HH01BFD-FLK Basic Type. Size: 96 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: position ratio with relay output.
Control output 2: position ratio with relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 4.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output E5AN-HAA2HH01BFD-FLK Manual.
Through the infrared port can be carried out from the frront of the communication E5AN-HAA2HH01BFD-FLK Manual.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.