Size: 48 * 48mm, terminal type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function E5CN-C2TU User's Manual.
Event entry point: 2.
Transfer output: -.
Communication: RS-485
E5CN-C2TU
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm) E5CN-C2TU User's Manual.
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can perform flexible contact output E5CN-C2TU User's Manual.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Fitting materials: Stainless steel(SUS304).
Count: 1 .
Accessories: Description, --;
Material, --;
Count, --.
Applicable sensor (mounting pitch on sensor side): E3T-FD@@M (8).
Page: Dimensions, 15. Item: Water-resistant models.
Connection method: Connector (M8).
Ratings and Specifications: Degree of protection: IP66.
Model: NPN output.
Simple and Affordable Fiber Amplifier Units.
Reasonable price.
Use the one-key one-function feature for quick,
easy operation.
GIGA RAY for the highest level of power in this class for,
stable detection even with sensing objects with low.
reflection or large sensing objects. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 1 dia.
Protective tubing length L: 15 cm.
Lead wire type: Heat resistive.
Lead wire length M : 1m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E5CN-C2TU Communications Functions MANUAL.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Teemperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E5CN-C2TU Communications Functions MANUAL.