OMRON E5CN-HR2H03D-FLK Manual E5CN-HR2H03D-FLK USER'S MANUAL
Product model: E5CN-HR2H03D-FLK
Name: Digital Temperature Controller
Brand: OMRON
Sort: USER'S MANUAL
File language: English
Appearance: Unshielded, M18.
Sensing distance: 8 mm.
Output configuration: DC 3-wire, NPN.
Model: Operation mode, NO.
General-purpose Threaded.
Capacitive Sensor.
Product lineup with M12, M18, and M30 models.
Fixed sensing distance requires no sensitivity adjustment. Control output: linear current output E5CN-HR2H03D-FLK USER'S MANUAL.
Auxiliary output: 2 points.
Heating wire break, SSR fault detection function: - E5CN-HR2H03D-FLK
Event input: -.
Communication: RS-485.
Terminal shape: screw terminal table type (main unit + terminal unit).
Power supply voltage: AC/DC24V.
DIN rail operation, high performance E5 / C series of the maintenance of the most suitable system connected with a touch screen /PLC and thermostat installation type E5CN-HR2H03D-FLK USER'S MANUAL.
DIN 85mm * 22.5MM width depth guide installation type, housed in the control cabinet of the thin slender body.
The terminal platform can be easily replaced, and the maintenance performance is improved.
Through the 50ms high speed sampling, suitable for the use of high speed heating.
Easy to connect with PLC through no program communication.
The use of communication adapter cable (sold separately) connected to the computer, without power supply connection
Set up。 It can be easily set by CX-Thermo (sold separately) E5CN-HR2H03D-FLK USER'S MANUAL.
With auxiliary output (maximum 2 points), event input (maximum 1 points), the basic function is complete.
The confirmation of a simple, eye-catching white PV display when starting or abnormal in the cabinet
(PV high 8.5mm). Size: 48 x 24mm.
Control output 1: linear current output.
Control output 2:--.
Auxiliary output: 2 points.
Power supply voltage: AC/DC24V.
Terminal type: PUSH-IN fastening terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: -.
Event input: 1 points.
A small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance.
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc..
Although the small size, but also through the character of the high 10.5mm white PV display to achieve high recognition.
The terminal stage is adopted to disassemble and assemble the structure, which improves the maintenance performance.
The connectionn method can be selected from a screw terminal and a PUSH-IN fastening terminal E5CN-HR2H03D-FLK Manual.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication.
The use of electric communication converrsion Village (sold separately) connected to the computer after,
No power connection can be set E5CN-HR2H03D-FLK Manual.
It can be easily set by CS-Thermo (sold separately).